GAS-FIRED WATER BOILER SERIES 2 — User’s <strong>Information</strong> <strong>Manual</strong>Maintenance procedures (continued)PeriodicallyTest low watercutoff (if installed)1. If the system is equipped with a low water cutoff, test the low water cutoff periodicallyduring the heating season, following the low water cutoff manufacturer’s instructions.Every 6 monthsCheck boiler piping(gas and water)Operate relief valve1. Remove boiler front access door and perform gas leak inspection per steps 1 through 7,Operating Instructions, page 9. If gas odor or leak is detected, immediately shut downboiler following procedures on page 9. Call a qualified service technician.2. Visually inspect for leaks around internal water piping. Also inspect external water piping,circulators, relief valve and fittings. Immediately call a qualified service technician torepair any leaks.Have leaks fixed at once by a qualifed service technician. Failure to complycould result in severe personal injury, death or substantial property damage.3. Replace door securely after inspections (see WARNING, page 6).1. Before proceeding, verify that the relief valve outlet has been piped to a safe place ofdischarge, avoiding any possibility of scalding from hot water.To avoid water damage or scalding due to valve operation, a metal dischargeline must be connected to relief valve outlet and run to a safe place of disposal.This discharge line must be installed by a qualifed heating installer or servicetechnician in accordance with the instructions in the Ultra Boiler <strong>Manual</strong>. Thedischarge line must be terminated so as to eliminate possibility of severe burnsor property damage should the valve discharge.2. Read the boiler pressure/temperature gauge to make sure the system is pressurized. Liftthe relief valve top lever slightly, allowing water to relieve through the valve and dischargepiping.3. If water flows freely, release the lever and allow the valve to seat. Watch the end of therelief valve discharge pipe to ensure that the valve does not weep after the line has hadtime to drain. If the valve weeps, lift the seat again to attempt to clean the valve seat. If thevalve continues to weep afterwards, contact your qualified service technician to inspectthe valve and system.4. If water does not flow from the valve when you lift the lever completely, the valve ordischarge line may be blocked. Immediately shut down the boiler, following the operatinginstructions on page 9. Call your qualified service technician to inspect the boiler andsystem.End of seasonShut boiler down(unless boiler usedfor domestic water)1. Follow “TO TURN OFF GAS TOAPPLIANCE” on the page 9 of thismanual.2. Do not drain system unless exposure tofreezing temperatures will occur.3. Do not drain the system if it is filled withan antifreeze solution.4. DO NOT shut down boilers used fordomestic water heating. They must operateyear-round.8Part number 550-100-027/0404

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!