13.07.2015 Views

User's Information Manual - Weil-McLain

User's Information Manual - Weil-McLain

User's Information Manual - Weil-McLain

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GAS-FIRED WATER BOILER SERIES 2 — User’s <strong>Information</strong> <strong>Manual</strong>Operating InstructionsFOR YOUR SAFETY READ BEFORE OPERATINGIf you do not follow these instructions exactly, a fire or explosion may resultcausing property damage, personal injury or loss of life.A. This appliance does not have a pilot. It is equipped withan ignition device which automatically lights the burner.Do not try to light the burner by hand.B. Before OPERATING, smell all around the appliance areafor gas. Be sure to smell next to the floor because somegas is heavier than air and will settle on the floor. Seebelow.C. Use only your hand to turn the gas control knob. Neveruse tools. If the knob will not turn by hand, don't try torepair it, call a qualified service technician. Force orattempted repair may result in a fire or explosion.D. Do not use this appliance if any part has been under water.Immediately call a qualified service technician to inspectthe appliance and to replace any part of the control systemand any gas control, which has been under water.• Do not try to light any appliance.• Do not touch any electric switch; do not use any phonein your building.WHAT TO DO IF YOU SMELL GASOPERATING INSTRUCTIONS• Immediately call your gas supplier from a neighbor'sphone. Follow the gas supplier's instructions.• If you cannot reach your gas supplier, call the firedepartment.1. Stop! Read the safety information above.This appliance is equipped with an ignitiondevice which automatically lights the burner.Do not try to light the burner by hand.2. Set room thermostat(s) to lowest setting.Verify external manual gas valve is open(valve handle parallel to gas piping).3. Turn OFF POWER switch on the Ultracontrol panel.4. Rotate two thumb screws at bottom of accessdoor counterclockwise to release door.5. Remove boiler access door.6. Turn boiler manual gas valve knobcounterclockwise to open gas supply.7. Smell for gas in the boiler enclosure. If yousmell gas, STOP! Follow "B" in the safetyinformation above. If you don't smell gas,go to the next step.8. Turn ON POWER switch on the Ultracontrol panel.9. Set thermostat(s) to desired setting.10. The Ultra control panel display left digitwill show a sequence of numbers (0, 1, 2,etc.) that indicate boiler control sequence.Digit 3 or 4 indicates boiler is firing.Digit 0 means there is no call for heat (allroom thermostats and domestic waterheater satisfied).11. If the appliance will not operate whenthere is a call for heat and piping is nothot, follow the instructions "To Turn OffGas To Appliance" below and call yourservice technician or gas supplier.12. Replace jacket front panel. Make surepanel is seated firmly in place and all jointsare visually sealed. Then tighten the twothumb screws at bottom of access doorfirmly.Boiler manualgas valveTO TURN OFF GAS TO THE APPLIANCE1. Set room thermostats to lowest setting.2. Turn off all electric power to the boiler if service is to beperformed. Turn OFF POWER switch on the Ultracontrol panel.3. Close external manual gas cock (valve handle perpendicularto gas piping). Remove boiler access door. Turn boilermanual gas valve knob clockwise to close gas supply.4. Replace boiler access door.Part number 550-100-027/0404 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!