13.07.2015 Views

The handbook of Technical irrigaTion informaTion - Hunter Industries

The handbook of Technical irrigaTion informaTion - Hunter Industries

The handbook of Technical irrigaTion informaTion - Hunter Industries

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

64Handbook <strong>of</strong> <strong>Technical</strong> Irrigation InformationTable <strong>of</strong> Voltage Losses for Annealed Copper Wire 25°C (77°F)(Loss per 1000 feet <strong>of</strong> wire)AMPERES 18 16 14 12 10 8 6 4 20.1 0.65 0.41 0.26 0.16 0.10 0.06 0.04 0.03 0.020.15 0.98 0.61 0.39 0.24 0.15 0.10 0.06 0.04 0.020.2 1.30 0.82 0.52 0.32 0.20 0.13 0.08 0.05 0.030.25 1.63 1.02 0.65 0.41 0.26 0.16 0.10 0.06 0.040.3 1.95 1.23 0.77 0.49 0.31 0.19 0.12 0.08 0.050.35 2.28 1.43 0.90 0.57 0.36 0.22 0.14 0.09 0.060.4 2.60 1.64 1.03 0.65 0.41 0.26 0.16 0.10 0.060.45 2.93 1.84 1.16 0.73 0.46 0.29 0.18 0.11 0.070.5 3.26 2.05 1.29 0.81 0.51 0.32 0.20 0.13 0.080.6 3.91 2.45 1.55 0.97 0.61 0.38 0.24 0.15 0.100.7 4.56 2.86 1.81 1.13 0.71 0.45 0.28 0.18 0.110.8 5.21 3.27 2.06 1.30 0.82 0.51 0.32 0.20 0.130.9 5.86 3.68 2.32 1.46 0.92 0.58 0.36 0.23 0.141.0 6.51 4.09 2.58 1.62 1.02 0.64 0.40 0.25 0.161.1 7.16 4.50 2.84 1.78 1.12 0.71 0.44 0.28 0.171.2 7.81 4.91 3.10 1.94 1.22 0.77 0.48 0.30 0.191.3 8.46 5.32 3.35 2.11 1.33 0.83 0.52 0.33 0.211.4 9.11 5.73 3.61 2.27 1.43 0.90 0.56 0.35 0.221.5 9.77 6.14 3.87 2.43 1.53 0.96 0.60 0.38 0.241.6 10.42 6.54 4.13 2.59 1.63 1.03 0.77 0.40 0.251.7 11.07 6.95 4.39 2.75 1.73 1.09 0.69 0.43 0.271.8 11.72 7.36 4.64 2.92 1.84 1.15 0.73 0.46 0.291.9 12.37 7.77 4.90 3.08 1.94 1.22 0.77 0.48 0.302.0 13.02 8.18 5.16 3.24 2.04 1.28 0.81 0.51 0.322.1 13.67 8.59 5.42 3.40 2.14 1.35 0.85 0.53 0.332.2 14.32 9.00 5.68 3.56 2.24 1.41 0.89 0.56 0.352.3 14.97 9.41 5.93 3.73 2.35 1.47 0.93 0.58 0.372.4 15.62 9.82 6.19 3.89 2.45 1.54 0.97 0.61 0.382.5 16.28 10.23 6.45 4.05 2.55 1.60 1.01 0.63 0.402.6 16.93 10.63 6.71 4.21 2.65 1.67 1.05 0.66 0.412.7 17.58 11.04 6.97 4.37 2.75 1.73 1.09 0.68 0.432.8 18.23 11.45 7.22 4.54 2.86 1.79 1.13 0.71 0.452.9 18.88 11.86 7.48 4.70 2.96 1.86 1.17 0.73 0.463.0 19.53 12.27 7.74 4.86 3.06 1.92 1.21 0.76 0.483.2 20.83 13.09 8.26 5.18 3.26 2.05 1.29 0.81 0.513.4 22.13 13.91 8.77 5.51 3.47 2.18 1.37 0.86 0.543.6 23.44 14.72 9.29 5.83 3.67 2.31 1.45 0.91 0.573.8 24.74 15.54 9.80 6.16 3.88 2.44 1.53 0.96 0.604.0 26.04 16.36 10.32 6.48 4.08 2.56 1.61 1.01 0.644.2 27.34 17.18 10.84 6.80 4.28 2.69 1.69 1.06 0.674.4 28.64 18.00 11.35 7.13 4.49 2.82 1.77 1.11 0.704.6 29.95 18.81 11.87 7.45 4.69 2.95 1.85 1.16 0.734.8 31.25 19.63 12.38 7.78 4.90 3.08 1.93 1.21 0.765.0 32.55 20.45 12.90 8.10 5.10 3.21 2.02 1.27 0.805.2 33.85 21.27 13.42 8.42 5.30 3.33 2.10 1.32 0.835.4 35.15 22.09 13.93 8.75 5.51 3.46 2.18 1.37 0.865.6 36.46 22.90 14.45 9.07 5.71 3.59 2.26 1.42 0.895.8 37.76 23.72 14.96 9.40 5.92 3.72 2.34 1.47 0.926.0 39.06 24.54 15.48 9.72 6.12 3.85 2.42 1.52 0.956.2 40.36 25.36 16.00 10.04 6.32 3.97 2.50 1.57 0.996.4 41.66 26.18 16.51 10.37 6.53 4.10 2.58 1.62 1.026.6 42.97 26.99 17.03 10.69 6.73 4.23 2.66 1.67 1.056.8 44.27 27.81 17.54 11.02 6.94 4.36 2.74 1.72 1.087.0 45.57 28.63 18.06 11.34 7.14 4.49 2.82 1.77 1.11To find the voltage loss for a two wire circuit, multiply the loss per 1000 feet figure above by twice the actual wirelength expressed in thousands. For a single wire, multiply the loss per 1000 feet value, above by the actual wire lengthin thousands.Note: Remember, amperages are additive along a wire where current is demanded by more than one appliance.Note: Voltage losses are calculated from the formula:Where: V = IR I = current in amperesR = resistance in ohms per 1000 feetV = voltage

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!