13.07.2015 Views

Dovre 550 Cast Iron Cleanburn Wood Stove - Harworth Heating Ltd

Dovre 550 Cast Iron Cleanburn Wood Stove - Harworth Heating Ltd

Dovre 550 Cast Iron Cleanburn Wood Stove - Harworth Heating Ltd

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Dovre</strong> <strong>550</strong> <strong>Cast</strong> <strong>Iron</strong> <strong>Cleanburn</strong> <strong>Wood</strong> <strong>Stove</strong>Installation and Operating ManualThese instructions should be readcarefully and saved by theuser for future referenceCONTENTSINTRODUCTION TOYOUR DOVRE STOVE Page 2UNPACKING Page 3GETTING THE BEST FROM YOUR STOVE Page 3LOCATION FOR THE INSTALLATION Page 3ASSEMBLY Page 4INSTALLATION Page 5CHIMNEY CONNECTIONS Page 5-6THE CHIMNEY Page 6-7OPERATING YOUR DOVRE STOVE Page 7SERVICING & MAINTENANCE Page 6-7GUIDE TO BURNING WOOD Page 7TROUBLE-SHOOTING Page 7WARRANTY DETAILS Page 7INTRODUCTION TO YOUR NEWDOVRE <strong>550</strong>CBWe would like to thank you for purchasing a <strong>Dovre</strong>stove and we trust that it will provide you with manyyears of useful service.At <strong>Dovre</strong> we have been producing cast iron stoves forover 60 years and we strive to ensure that our productsmeet with the highest level of performance, efficiency,safety and quality. So much so that we guarantee all<strong>Dovre</strong> body castings for 10 years.Owning a stove might be a new experience for you.Therefore, to ensure that you get the best performancefrom your new <strong>Dovre</strong>, do please take a little time to readthrough this manual.The <strong>550</strong> CB is a specially designed stove for burningwood with clean emissions. It is essential that whenwood is used, it is well seasoned for a minimum of 2years and has maximum moisture content of 20%. Ifunseasoned wood is used, heat outputs will not beobtained and serious damage will occur in the chimneyand flueways.The dimensions of your new stove are illustrated in fig.1. Be careful to ensure that your fireplace is going toaccept the appliance and that you have allowed for atleast 225mm of hearth space in front of the stove.Your <strong>Dovre</strong> <strong>550</strong> CB is constructed from high-grade quality castiron and is therefore not light in weight. We recommend that twopeople are available to handle the unit.Before taking your <strong>Dovre</strong> to its installation location, remove theouter packing. Open the appliance door.Remove the following components:■ Ashpan■ Fixings pack■ <strong>Cast</strong> iron grate centre■ Ash rakeCheck that the following parts are in the Fixings Pack.■1 Tub 400 gm Fire Cement■ <strong>Cast</strong> <strong>Iron</strong> Flue Spigot (part number 003410)■ 2 Decorative Blanking Plates part number 153280)■ 1 Plain Blanking Plate (part number 153320)■ 3 Blanking Plate retaining bars (part number 072160)■ 4 Legs (part number 522190)■ 4 Leg extensions (part number 522200)■■■■■UNPACKING YOUR DOVRE <strong>550</strong>CBL shaped handle support bracketOperating Tool (part number SLT5/01)Pack containing over plate remover and instructionsheet. (Part number 72301.0)Miscellaneous fixing pack including fixing screws anddoor handleQuality control ticket (IMPORTANT TO RETAINTICKET IN CASE OF FUTURE CLAIMS)GETTING THE BEST FROM YOUR DOVRE 250There are 4 golden rules to follow:1 USE GOOD FUEL - NEVER BURN UNSEASONED OR DAMPWOOD2 YOU MUST HAVE A GOOD CHIMNEY DRAUGHT - NEVERUSE YOUR DOVRE STOVE WITH A POOR CHIMNEY3 AVOID OPERATING THE STOVE FOR LONG PERIODS ONCONTINUOUS LOW TEMPERATURE4 NEVER USE SOLID FUEL ON YOUR DOVRE <strong>550</strong>CBLOCATION FOR THE INSTALLATIONThe location in which your stove is to be installed will of coursedepend on the chimney available. If you do not have a chimney,there are a number of prefabricated flue systems available andyour <strong>Dovre</strong> Dealer will be pleased to offer guidance on the subject.Building Regulations must be observed when considering thelocation of your <strong>Dovre</strong>. More precise information can be foundlater in this manual but it is important to ensure that a suitablehearth, complying with Building Regulations, is available.NEVER ALLOW A MECHANICAL AIR EXTRACTOR TO BE USEDIN THE ROOM OR ADJOINING ROOMS AS THIS COULD CAUSETHE APPLIANCE TO EMIT SMOKE INTO THE ROOM.IMPORTANT - FLUE CLEANINGIt is essential that an access point for cleaning the chimneybe incorporated in the installation. This can normally becarried out by fitting an external soot door or access platein the flue pipe. Access for rear flue connections can bemade using a tee section soot trap at the base of the fluepipe. See fig.3 below.Your <strong>550</strong>CB is equipped with a special top baffle platedesigned to direct pre-heated secondary combustion air. Itis essential that access be allowed for cleaning the topsideof the baffle.<strong>550</strong>150WE DO RECOMMEND THAT WHEREVER POSSIBLE,YOUR DOVRE IS FITTED BY AN EXPERIENCEDINSTALLER ACCUSTOMED TO THE INSTALLATIONOF CLASS 1 SOLID FUEL BURNING APPLIANCES.Assemble the handle referring to fig.2 belowREAR FLUE CONNECTIONSOOT DOORTOP FLUE CONNECTIONSOOT DOOR765640If you are unsure about any aspect of the installation oroperation procedures, your <strong>Dovre</strong> dealer will be pleasedto help.SOOT DOORIt is important that the Installation is carried out incompliance with current Building Regulations.440FIG.1. STOVE DIMENSIONSFIG.2 HANDLE ASSEMBLYFIG.3 SOOT DOOR LOCATION23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!