13.07.2015 Views

YS05S16 DC-DC Converter Data Sheet - Power-One

YS05S16 DC-DC Converter Data Sheet - Power-One

YS05S16 DC-DC Converter Data Sheet - Power-One

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>YS05S16</strong> <strong>DC</strong>-<strong>DC</strong> <strong>Converter</strong> <strong>Data</strong> <strong>Sheet</strong>3.0-5.5 V<strong>DC</strong> Input; 0.7525-3.63 V<strong>DC</strong> Programmable @ 16 ATable 1: Trim Resistor ValueV 0-REG [V] R TRIM [kΩ]The ClosestStandard Value [kΩ]0.7525 open1.0 80.0 80.61.2 41.97 42.21.5 23.1 23.21.8 15 152.0 11.78 11.82.5 6.95 6.983.3 3.16 3.163.63 2.21 2.21The output voltage can also be programmed byexternal voltage source. To make trimming lesssensitive, a series external resistor Rext isrecommended between TRIM pin and programmingvoltage source. Control Voltage can be calculated bythe formula:(5.11REXT)(VO-REQ- 0.7525)VCTRL 0.7 [V]30.1where,VCTRL Control voltage [V]REXT External resistor between TRIM pin andvoltage source; the value can be chosen dependingon the required output voltage range [kΩ].Control voltages withshown in Table 2.REXT 0 and REXT 15K areTable 2: Control Voltage [V<strong>DC</strong>]V 0-REG [V] V CTRL (R EXT = 0) V CTRL (R EXT = 15K)0.7525 0.700 0.7001.0 0.658 0.5351.2 0.624 0.4011.5 0.573 0.2011.8 0.522 -0.0002.0 0.488 -0.1332.5 0.403 -0.4683.3 0.268 -1.0023.63 0.257 -1.044Protection FeaturesInput Undervoltage LockoutInput undervoltage lockout is standard with thisconverter. The converter will shut down when theinput voltage drops below a pre-determined voltage;it will start automatically when Vin returns to aspecified range.The input voltage must be typically 2.05 V for theconverter to turn on. Once the converter has beenturned on, it will shut off when the input voltagedrops below typically 1.9 V.Output Overcurrent Protection (OCP)The converter is protected against overcurrent andshort circuit conditions. Upon sensing an overcurrentcondition, the converter will enter hiccup mode. Onceover-load or short circuit condition is removed, Voutwill return to nominal value.Overtemperature Protection (OTP)The converter will shut down under anovertemperature condition to protect itself fromoverheating caused by operation outside the thermalderating curves, or operation in abnormal conditionssuch as system fan failure. After the converter hascooled to a safe operating temperature, it willautomatically restart.Safety RequirementsThe converter meets North American andInternational safety regulatory requirements perUL60950 and EN60950. The maximum <strong>DC</strong> voltagebetween any two pins is Vin under all operatingconditions. Therefore, the unit has ELV (extra lowvoltage) output; it meets SELV requirements underthe condition that all input voltages are ELV.The converter is not internally fused. To comply withsafety agencies’ requirements, a recognized fusewith a maximum rating of 20 Amps must be used inseries with the input line.CharacterizationGeneral InformationThe converter has been characterized for manyoperational aspects, to include thermal derating(maximum load current as a function of ambienttemperature and airflow) for vertical and horizontalmountings, efficiency, startup and shutdownparameters, output ripple and noise, transientresponse to load step-change, overload, and shortcircuit.MCD10205 Rev. 1.0, 24-Jun-10 Page 7 of 25 www.power-one.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!