Infinity Operations Manual (96402,96403, 96406, 96407) - Whip Mix
Infinity Operations Manual (96402,96403, 96406, 96407) - Whip Mix
Infinity Operations Manual (96402,96403, 96406, 96407) - Whip Mix
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ERROR CODESerrorcode DESCRIPTION PROBABLE CAUSEEr 6Er 7SHORTEDTHERMOCOUPLE ORDEFECTIVE HEATERPLATESTHERMALRUNAWAYOccurs if the thermocouple wires are shorted or the heater plates aredefective causing <strong>Infinity</strong> to achieve a HEAT RATE of less than 6% of themaximum attainable HEAT RATE with full power applied to the heaterplates for 5 minutes. This error will also occur if a program is runningand the door is kept open for more than 5 minutes or the relay or theMain PC board developed a problem during a burnout process.Occurs when the temperature has exceeded 2015°F (1102°C) for 1minute if the highest temperature programmed was less than 2000°F(1093°C). This also occurs when the temperature has exceeded 2050°F(1121°C) for 1 minute if the highest temperature programmed was2000°F (1093°C) or higher.Flashing99:99 whenNIGHT / TIMESET (DELAYSTART) ispressedduring aprograminvalid entryerror while aprogram isrunningOccurs when the HEAT RATE in STAGE 2, 3 or 4 is set to “COOL” butthe corresponding TEMP is entered to heat to a higher temperaturethan the previous stage.18