13.07.2015 Views

Insulation monitor - GMWISO 1.05 - gts generator. technik. systeme.

Insulation monitor - GMWISO 1.05 - gts generator. technik. systeme.

Insulation monitor - GMWISO 1.05 - gts generator. technik. systeme.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Insulation</strong> <strong>monitor</strong> - <strong>GMWISO</strong> <strong>1.05</strong>Warnings and informations on generatots with <strong>GMWISO</strong>Since the stand-by electric-power <strong>generator</strong>s equipped with the system ofprotection "Fuse disconnection with insulation <strong>monitor</strong>ing and cut-off" have mainlybeen conceived for the use by non-electricians, it must be possible for all users ofthe stand-by electric-power <strong>generator</strong> to safely operate the stand-by electric-power<strong>generator</strong> and to test the additional safety measure against direct contact. Bothmust be identified at the device.At least the following instructions must be attached visibly and permanently to theelectric-power <strong>generator</strong>.COMMENT: Depending on the electric-power <strong>generator</strong> or its purpose, it might benecessary to attach or enclose further instructions. The exemplary text refers tothe operation of the GMW-SYNCHRO stand-by electric-power <strong>generator</strong>.Short operator's guide/information− Used safety measure: "Fuse disconnection with insulation <strong>monitor</strong>ing and all-poloCut-off".− This device can be operated without grounding.− The following tests must be carried out daily with the motor running:1. Unplug all devices; open the cover; safety switch in position "ON",2. press the test button,3. check whether the safety switch has triggered and the signal lainp has beenactivated,4. stop the electric?power <strong>generator</strong>,5. safety switch in position "ON", close the cover.− NOTICE: The electric-power <strong>generator</strong> may only be used if the safety switchtriggered during the test.− The total length of all lines connected to the electric-power <strong>generator</strong> mustntexceed 250 m.− If several stand-by electric-power <strong>generator</strong>s are used or if the general networkis also available, the networks mustn't be connected to each other.− Corrective maintenance at the electrical components of the stand-by electricpower <strong>generator</strong> and at the electric equipment may only be carried out byelectricians.− For further safety and operating inforination, please refer to the Operator'sGuide and the relevant regulations.GTS GmbH & Co. KG, Ziegelfeldstraße 18, D - 73563 Mögglingen,Telefon: +49 (0) 7174/89800-0, Telefax: +49 (0) 7174/89800-257

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!