13.07.2015 Views

PC T5 PRO-M lp 14–80 W - Tridonic

PC T5 PRO-M lp 14–80 W - Tridonic

PC T5 PRO-M lp 14–80 W - Tridonic

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

FL ballastsElectronic fixed outputStandardsEN 55015EN 61347-2-3EN 60929EN 61000-3-2EN 61000-3-3EN 61547according to EN 50172IEC 60068-2-64 FhIEC 60068-2-29 EbIEC 60068-2-30<strong>PC</strong> <strong>PRO</strong>-M with xitec processorIs the very latest in lighting management design technology. The lamp friendlywarm start is delivering maximum lamp life and enables high switching frequencyapplications. Smallest power loss and new freedom in the lamp design thanksto convincing thermal management.Multi-lampMulti-lamp functionality comprises an additional circuit that automaticallydetects lamps before they are ignited. After detection the predefined operatingparameters stored in an internal memory are retrieved and activated and thelight source is then started. This enables a wide variety of lamp types to be operatedon only one device.Smart HeatingInnovative heating circuit. Reduced filament heating after lamp ignition.Energy class CELMA EEI = A2 BAT / A2 1)<strong>PC</strong> <strong>T5</strong> <strong>PRO</strong>-M ignition technology (smart heating) optimises lamp start andensures no energy is wasted. After the lamp has struck the filament heating isreduced automatically to a defined minimum value. This reduction in filamentheating, saves energy, yet maintains the proper operating conditions for thelamp. The lamp is always operated within specification.Lamp starting characteristicsWarm startStarting time 0.5 secs with AC and DC operationCathode heating will be reduced after preheat timeAC operationMains voltage:220–240 V 50/60 Hz198–264 V 50/60 Hz including safety tolerance (±10 %)202–254 V 50/60 Hz including performance tolerance (+6 % / -8 %)DC operation220–240 V 0 Hz198–280 V 0 Hz certain lamp start176–280 V 0 Hz operating rangeLight output level in DC operation: 100 %Emergency lightingUse in emergency lighting installations according to EN 50172 or for emergencyluminaires according to EN 61347-2-3 appendix J.Instant start after mains interruption < 0.5 sEBLF = 1.00Intelligent Voltage GuardIntelligent Voltage Guard is the name of the new electronic monitor from <strong>Tridonic</strong>. Thisinno vative feature of the <strong>PC</strong> <strong>PRO</strong>-M family of control gear from <strong>Tridonic</strong> immediatelyshows if the mains voltage rises above or falls below certain thresholds. Measures canthen be taken quickly to prevent damage to the control gear.• If the mains voltage rises above 306 V the lamps start flashing on and off.• This signal “demands” disconnection of the power supply to the lightingsystem.• If the mains voltage falls below 150 V the control gear automatically disconnectsthe lamp circuit to protect the control gear from being irreparablydamaged.1)according to the EU directives on ecodesign requirements (EC) No. 245/2009and (EC) No. 347/2010Ballast / lamp combinations<strong>T5</strong> HE <strong>T5</strong> HO <strong>T5</strong>c T8 TC-F TC-LType 14 W 21 W 28 W 35 W 24 W 39 W 49 W 54 W 80 W 22 W 40 W 55 W 18 W 30 W 36 W 58 W 18 W 24 W 36 W 18 W 24 W 36 W 40 W 55 W 80 W<strong>PC</strong> 1/14-35/24/39 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> • • • • • • • • • • • • • • • • • •<strong>PC</strong> 1/14-35/49/54 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> • • • • • • •<strong>PC</strong> 1/14-35/49/80 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> • • • • • • • • • •<strong>PC</strong> 2/14-21/24/39 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> • • • • • • • • • • • • • • •<strong>PC</strong> 2/14-35/49/54 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> • • • • • • •Ambient Temperature78 mm110 mmtcThe nominal ta and tc point are related to theballast life duration.The relation of tc to ta temperature dependsalso on the luminaire design. If the measuredtc temperature is approx. 5 K below tc max.,ta temperature should be checked and eventuallycritical components (e.g. ELCAP) measured.Detailed information on request.<strong>PC</strong> <strong>T5</strong> <strong>PRO</strong>-M is designed for an average servicelife of 50,000 hours under reference conditionsand with a failure probability of less than 10 %.This corresponds to an average failure rate of0.2 % for every 1,000 hours of operation.Maximum loading of automatic circuit breakersAutomatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Inrush currentInstallation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 I maxPulse<strong>PC</strong> 1/14-35/24/39 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> 32 42 50 60 16 21 25 30 24.1 A 154 µs<strong>PC</strong> 1/14-35/49/54 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> 31 41 50 60 16 21 25 30 26.2 A 168 µs<strong>PC</strong> 1/14-35/49/80 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> 14 18 22 26 7 9 11 13 37.9 A 209 µs<strong>PC</strong> 2/14-21/24/39 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> 22 28 35 44 14 17 20 24 33.9 A 168 µs<strong>PC</strong> 2/14-35/49/54 <strong>T5</strong> <strong>PRO</strong>-M <strong>lp</strong> 14 18 22 26 7 9 11 13 37.9 A 193 µsData sheet 10/14-802-14Subject to change without notice.www.tridonic.com 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!