13.07.2015 Views

PASS M0 - Innovative solutions for distribution substations up to

PASS M0 - Innovative solutions for distribution substations up to

PASS M0 - Innovative solutions for distribution substations up to

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

General descriptionCircuit -breakerThe <strong>PASS</strong> <strong>M0</strong> circuit-breaker is a single pressureinterr<strong>up</strong>ter operating on the well-established selfblastprinciple.The energy <strong>for</strong> interr<strong>up</strong>ting currents is partlys<strong>up</strong>plied by the arc itself, thereby reducing theenergy requested from the operating mechanismof about 50% compared with a conventionalpuffer-type circuit-breaker.Combined Disconnec<strong>to</strong>r/Earthing Switch<strong>PASS</strong> <strong>M0</strong> is equipped with a three pole operatedcombined disconnec<strong>to</strong>r/earthing switch. Theoperating principle (patented) is based <strong>up</strong>on therotary motion of the contact which can be closedon the BusBar, earthed or left in the neutralposition.The mechanism is composed of minimal numberof mechanical components and it is intrinsicallyreliable, and maintenance free. This modulardesign can be applied <strong>to</strong> <strong>PASS</strong> <strong>M0</strong> in SingleBusBar configuration, Double BusBarconfiguration and on all the bushings: BusBar orline sides.All the combinations are possible.In both cases, Single BusBar and Double BusBar,the position of the combined disconnec<strong>to</strong>r/earthing switch is clearly indicated at all times byan indica<strong>to</strong>r which is mechanically co<strong>up</strong>led <strong>to</strong> theshaft. In addition <strong>to</strong> this, a visual confirmation ispossible by means of a view port in the enclosure.The disconnec<strong>to</strong>r/earthing switch may, in anemergency, be operated manually by means of acrank.Current Trans<strong>for</strong>mer<strong>PASS</strong> <strong>M0</strong> is equipped with a conventional currenttrans<strong>for</strong>mer, <strong>to</strong> meet cus<strong>to</strong>mer requirements, e.g.<strong>for</strong> retrofitting. Several combinations of cores <strong>for</strong>protection and measurements with differentburdens are available. Up <strong>to</strong> 5 cores can be fittedin<strong>to</strong> the current trans<strong>for</strong>mer.BushingsOverhead lines and BusBars are connected <strong>to</strong> the<strong>PASS</strong> <strong>M0</strong> by air bushings. The main insulation iscompressed SF6-gas. The insula<strong>to</strong>r consists of anepoxy impregnated fibreglass tube with siliconrubber sheds. The flanges are heatshrunk andglued on<strong>to</strong> the tube making an extremely strongand gastight joint. The silicon rubber sheds arecast on<strong>to</strong> the tube and chemically bonded <strong>to</strong> it,thus allowing no moisture or contamination <strong>to</strong>enter between them. The silicon rubber sheds arehydrophobic and give very good rain and pollutionper<strong>for</strong>mance. The main features are:Fig. 4The operating mechanism is of the spring type. This typeof drive s<strong>to</strong>res energy in a spring which is dischargedduring operations.• high safety (crack and explosion resistant)• low weight• excellent pollution and rain per<strong>for</strong>mance• sands<strong>to</strong>rm resistant• maintenance free.SF6 Gas SystemThe compact design of the <strong>PASS</strong> <strong>M0</strong> module isdue <strong>to</strong> the excellent insulation qualities of SF6gas. Its dielectric strength in a homogeneous fieldis about 2.5 times greater than that of air at thesame temperature and pressure. The design of thelive components is such that the field <strong>distribution</strong>is as homogeneous as possible, which allows theintrinsic strength of the insulating gas <strong>to</strong> be utilizedmost efficiently.❑ SF6 gas pressures of the <strong>PASS</strong> <strong>M0</strong>module at 20 °C• Filling pressure ........................ 680 kPa (abs)• First alarm level ........................ 620 kPa (abs)• Nominal insulation pressure(blocking pressure) ................ 600 kPa (abs)Filling pressure is about 15% higher than thenominal insulation pressure. This guaranteessufficient gas density over a long operationalperiod. To ensure minimum gas loss duringoperation all enclosures, connections and valvesare subjected <strong>to</strong> severe gas-tightness tests in thefac<strong>to</strong>ry.❑ Gas density controlEach <strong>PASS</strong> <strong>M0</strong> pole builds a single gas compartment.Since the dielectric strength of the switchgear andthe breaking capacity of the SF6 circuit-breakerdepend on the density of the SF6 gas, a gas densityrelay is installed <strong>to</strong> control gas density and detectleakage.4 - <strong>PASS</strong> <strong>M0</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!