13.07.2015 Views

PASS M0 - Innovative solutions for distribution substations up to

PASS M0 - Innovative solutions for distribution substations up to

PASS M0 - Innovative solutions for distribution substations up to

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>PASS</strong> <strong>M0</strong> technical dataGeneral RatingsRated frequency ..................................................................................................................................... 50/60 HzRated voltage .......................................................................................... 170 kV ............... 72,5/123/145/170 kVRated current ....................................................................................................................................... .2500 A (1)Max. test voltage:a) Phase <strong>to</strong> ground:Rated short time power frequency withstand voltage, 1 min ......... 325 kV ................ 140/230/275/275 kVRated lightning impulse withstand voltage 1,2/50 µs ...................... 750 kV ................ 325/550/650/650 kVb) Across isolating distance (circuit-breaker, disconnec<strong>to</strong>r):Rated short time power frequency withstand voltage, 1 min ......... 375 kV ................ 160/265/315/315 kV.Rated lightning impulse withstand voltage 1,2/50 µs ...................... 860 kV ................ 375/630/750/750 kVRated short time withstand current (3 s) ..................................................................................................... 40 kARated peak withstand current .................................................................................................................... 100 kAAmbient temperatureMin. (2) ............................................................................................... -25 °C ...................................... - 30 °CMax. ..................................................................................................................................................... + 55 °CGas loss per year ......................................................................................................................................... < 1%WeightSingle BusBar ..................................................................................................................................... 1900 kgDouble BusBar ................................................................................................................................... 2150 kgIncoming - outgoing ............................................................................................................................ 2300 kgSF6 pressures (20 °C) (absolute values)Filling pressure ............................................................................... 700 kPa .................................... 680 kPaFirst alarm level .............................................................................. 660 kPa .................................... 620 kPaNominal insulating pressure (blocking pressure) ......................... 640 kPa ................................... .600 kPa(1) Up <strong>to</strong> 3150 A, on request.(2) Lower temperatures can be reachedby a gas mixture on request.Circuit-breakerSingle interr<strong>up</strong>ter, type LTB-DRated short circuit breaking current ..................................... 40kA / 50 HzRated short circuit breaking current ..................................... 40kA / 60 HzRated short circuit making current (close and latch) ............... 100 kA pK.Line charging switching ............................................................................... 63ACable charging switching .......................................................................... 160ADrive ........................................................ 3 poles spring operated / Single poleType ....................................................................................... BLK 222 / BLK 82Rated operating sequence ............................................. O-0.3 s-CO-1min-COOpening time ......................................................................................... =

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!