13.07.2015 Views

New micro size drive STARVERT - Bermar.it

New micro size drive STARVERT - Bermar.it

New micro size drive STARVERT - Bermar.it

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>New</strong> <strong>micro</strong> <strong>size</strong> <strong>drive</strong><strong>STARVERT</strong>Parameter Descriptions▒ Program group*Note1)DisplayP10P11P12P13P14P15P17P18Output block time beforeDC brakingDC braking volumeDC braking timeDC braking volume atign<strong>it</strong>ionDC braking time of ign<strong>it</strong>ionJog frequencyStandard frequencyStarting frequency0 ~ 60 [sec]0 ~ 200 [%]0 ~ 200 [%]0 ~ 60 [sec]0 ~ 200 [Hz]30 ~ 200 [Hz]0.1 ~ 10 [Hz]Output is blocked for set up time and starts DC braking.DC current <strong>size</strong> that flows to motor.The standard is motor rated current (P43).DC time that flows to motor.DC current volume that flows to motor before <strong>it</strong> spins.Motor rated current (P43).DC current flows to motor for scheduled time at ign<strong>it</strong>ion.Jog operation frequency can be set.The frequency can not be set over maximum frequency(P16).0 XFrequency setting related maximum value of parameters.The standard frequency of Acc/Dec lean.P16 Maximum frequency 40 ~ 200 [Hz] ☞Note : Once the maximum frequency value is changed, all parameter 60.0 Xvalues other than P17(standard frequency) are changed as themaximum frequencies that are all over the maximum frequencies.0 Manual torque boostP19 Torque boost selection 0 ~ 10 X1 Automatic torque boostP20P21Function Setting range Description Factory default Mode changeduring runForward operationtorque boostReverse operationtorque boost0 ~ 60 [sec]0 ~ 15 [%]0 ~ 15 [%]The output frequency w<strong>it</strong>hin which the <strong>drive</strong> output equals to therated voltage of motor.The minimum parameter value of frequency level.The boost volume, in case of forward operation, that flows to motor.In case of maximum output voltage.The boost volume, in case of reverse operation, that flows to motor.The maximum output voltage is standard.0.1 X50 X1.0 X50 X10.060.0 X0.5 X5 X5 X0 LinerP22 V/F pattern 0 ~ 10 X1 SquareP23 Output voltage control 40 ~ 110 [%]Output voltage <strong>size</strong> control. The input voltage is standard.100 XBlocking the <strong>drive</strong> output in case of overload.P24 Overload trip selection 0 ~ 11The overload protection function is activated if user sets as umber 1.Overload current <strong>size</strong> setting.P25 Overload trip level 50 ~ 200 [%]180Motor rated current (P43) is standard.P26P27P28Overload trip timeStall preventionselectionStall prevention level0 ~ 60 [sec]b<strong>it</strong> 2 b<strong>it</strong> 1 b<strong>it</strong> 00 ~ 701234567----vvvv--vv--vv-v-v-v-v0X30 ~ 150 [%]Drive blocks output if the overload trip level(P25) current flows for theoverload trip time.Decelerating in acceleration or normal operation.Deceleration is stopped during deceleration operation.Stall preventionduring decelerationStall preventionduring normaldecelerationStall preventionduring accelerationdecelerationDisplaying the stall prevention current <strong>size</strong> during acceleration ornormal operation in terms of percent(%).The motor rated current(P43) is standard.60150XP29Up/Down frequencysave selection0 ~ 1Selecting the set frequency for up/down operation.If user chooses number 1, <strong>it</strong> is saved onto up/down frequency(P30).0XP30Up/Down frequency save-Displaying up/down operation stop or before acceleration frequency.0.00-P31Dwell frequency0.1 ~ 200 [Hz]Once operation command is inputted, first outputs the dwell frequencyduring dwell time(P32) and then starts acceleration.Dwell value can be set between the maximum frequency P16and starting frequency P18.5.0XP32Dwell time0~10 [sec]Dwell operation time setting0.0X*Note1) The P8 has to be set as 1 (DC braking stop)<strong>STARVERT</strong> iE5 _ 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!