13.07.2015 Views

New micro size drive STARVERT - Bermar.it

New micro size drive STARVERT - Bermar.it

New micro size drive STARVERT - Bermar.it

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>New</strong> <strong>micro</strong> <strong>size</strong> <strong>drive</strong><strong>STARVERT</strong>Standard Specification▒ Basic specificationModel : SV iE5 - 001-1 002-1 004-1 001-2 002-2 004-2[HP]Applicable motor[kW]Rated capac<strong>it</strong>y [kVA]Rated current [A]Rated outputOutput frequency [Hz]Output voltage [V]Applicable voltage [V]Rated input Input frequency[Hz]Rated current [A]1/80.10.30.81/40.20.61.41/20.40.952.51/80.10.30.81/40.20.61.61/20.41.143.00 ~ 200 [Hz]3 phase 200 ~ 230V1 phase 200 ~ 230 VAC (±10%) 3 phase 200 ~ 230 VAC (±10%)50 ~ 60 [Hz] (±5%)2.03.55.51.22.03.5▒ Control▒ OperationControl typeV/F ControlOperationOperation method can be selected betweenFrequency setDig<strong>it</strong>al command : 0.01Hzmethodloader, terminal and communication operationresolutionAnalog command : 0.06Hz (Max.frq : 60Hz)Dig<strong>it</strong>al command :Frequency setAnalog method : 0~10(V), 0~20(mA), Loader volumeDig<strong>it</strong>al method : LoaderFrequency accuracy0.01% of Max. Output frequencyAnalog command :OperationfunctionPI Control, Up-Down , 3-wire operation0.1% of Max. Output frequencyNPN / PNP SelectableV/F patternLinear, Squared, User V/FOverload capac<strong>it</strong>y 150% / 1MinTorque boost Manual / Auto torque boost*Note1) The standard of rated capac<strong>it</strong>y is 220V.*Note2) The maximum output voltage does not increase over input voltage and the outputvoltage can be set below input voltage level.InputMultifunctionterminal (5points)P1,P2,P3,P4,P5FWD/REV operation, Fault reset, Jog operation, Multistepfrequency(up/down), DC braking in stop mode,Frequency increase, Frequency decrease, 3 wireoperationexternal trip A and B, Shift to generaloperation from PI operation. Analogue commandfrequency set, Up/down save frequency deleteMultifunctionrelayterminalFault and <strong>drive</strong> operation cond<strong>it</strong>ion output(N.). N.C) AC250V below 0.3A and below DC 30V 1AAnalogueoutput0~10Vdc(below 10mA) : can be selected amongfrequency, current, voltage, DC voltage▒ Protection▒ Guaranteed operation cond<strong>it</strong>ionTripOver voltage, Under voltage, Over current, Ground fault,Drive overload, Overload trip, Overheat, Condensoroverload, Phase loss overload protection, Frequencycommand loss, Hardware faultCoolingEnclosureAmbient temperatureProtection temperatureOpen coolingIP20 (open type)-10℃ ~ 65℃-20℃ ~ 65℃AlarmStall preventionHumid<strong>it</strong>yBelow 90% RH (non-condensation)Momentarypower lossBelow 15msec : Operation continued (should be w<strong>it</strong>hinrated input voltage and rated output)Over 15msec : Auto re-ign<strong>it</strong>ion operation.Alt<strong>it</strong>ude/VibrationInstallation cond<strong>it</strong>ionBelow 1000m, 5.9m/sec square (0.6G)No corrosive gas, No flammable gas, Nooil mist, No dust<strong>STARVERT</strong> iE5 _ 7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!