J.A. Cesare & Associates, Inc. / Construction Technical Services7108 South Alton Way, Bldg. B,Centennial, CO 80112Phone: (303) 783-9965; Fax: (303) 783-9964CONCRETE MIX DESIGN VERIFICATIONProject Number: D06.348 Report Date:Project Name: Mitigation Materials for ASR in Concrete Technician:mw/zbLab ID Number: 75199.M Reviewer:Date Batched 1/3/2008Description:Client:Concrete Mix Design by: Grand Junction Ready Mix Date Performed: 3-Jan-08Client Mix Design ID: CDOT class D Lab Batch Size, CF 1.5DesignVerificationCalculatedMaterial Source and Type Specific GravityBatch Weights(yd 3 ) Cubic FeetBatch Weights(lbs)Cement (ASTM C 150) Holcim Type I/II GU 3.15 475 lb 2.42 26.39Fly Ash (ASTM C 618) GCC Microsilex 2.30 185 lb 1.29 10.28*Coarse Aggregate (ASTM CGrand Junction Pipe Soaring33)Eagle Pit #67 2.64 1219 lb 7.40 67.72*Coarse Aggregate (ASTM CGrand Junction Pipe Soaring33)Eagle Pit #8 2.61 528 lb 3.24 29.33*Fine Aggregate (ASTM C 33) Grand Junction Pipe 23rd Road Pit 2.65 1165 lb 7.05 64.72Water Municipal 1.00 275 lb 4.41 15.28Air Entraining Agent (ASTM C260) BASF Micro Air n/a 1.0 oz 0.00 0.06Water Reducer-Normal (ASTM(C494) BASF 3030NS n/a 5.0 oz 0.00 0.28E-13