13.07.2015 Views

TRANQUILITY WOOD STOVE - Home Depot

TRANQUILITY WOOD STOVE - Home Depot

TRANQUILITY WOOD STOVE - Home Depot

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

INSTALLATIONWARNINGDO NOT INSTALL IN A SLEEPING ROOM.CAUTIONTHE STRUCTURAL INTEGRITY OF THEMANUFACTURED HOME FLOOR, WALL ANDCEILING/ROOF MUST BE MAINTAINED.CautionNEVER draw outside combustion air from:Wall, floor or ceiling cavity orenclosed space such as an attic, garage or crawlspace.Mobile <strong>Home</strong> Installation• The wood stove MUST be secured to the floor of the mobile home using lag bolts and the holesprovided in the bottom of the unit for thisChimney Cap/Spark Arrestorpurpose.• The wood stove must be connected to thechimney system with double wall chimneyconnector which is UL listed for use in mobileand manufactured homes.• Carefully follow all clearances listed in theappropriate section of this manual AND followthe venting manufacturer’s minimumclearance requirements. Similarly, be certainthe venting system used is approved formobile home use.• Installation must be in accordance withManufacturers <strong>Home</strong> & Safety Standard (HUD)CFR 3280, Part 24 as well as any applicable local codes.Outside Combustion Air• The use of outside combustion air is mandatory when installing this wood stove in a mobile ormanufactured home.• The outside air connection pipe protrudes from the bottom center of the stove; a kit is availablefrom England’s Stove Works, Inc. designed for connecting this unit to outside combustion air. [PartNo. AC‐OAK5]• If it is not feasible to use the AC‐OAK5 outside air hookup kit in your stove installation, othermaterials may be used, provided the following rules are followed:oooClass A Chimney SystemRoof Flashing and Storm CollarJoist Shield/FirestopMobile <strong>Home</strong> Approved DoubleWall Chimney ConnectorUse silicone to create a vaporbarrier where the chimney passesthrough to exterior.The pipe used for outside air hookup must be metal, with a minimum thickness of .0209in.(25 gauge mild steel) or greater and an inside diameter of approximately 4.25in.Keep pipe runs short and use a mechanical fastener at each pipe joint.A screen or other protection device must be fitted over the outside air termination point toprevent rain, debris and nuisance animals from entering the piping system. Inspect theoutside combustion air inlet for block and debris monthly.Page | 14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!