Section 9: System Care9.1 Daily MaintenanceIt is recommended that you perform the followingmaintenance procedures to help minimize bio-filmformation in the water path of your Cavitron BOBCAT Proultrasonic scaler which could affect the water flow to theultrasonic insert, and scaling performance.Start-Up Procedures at the beginning of the day:1. Open the manual shut-off valve on the dental officewater supply system.2. Turn the System ON using the ON/OFF control switch.(See illustration on page 5). Verify the Power IndicatorLight is lit.3. Set the Power Control knob to the minimum setting.4. Set the Water Control knob to maximum.5. Hold the Handpiece (without an insert installed) uprightover a sink or drain. Activate the Foot Control and flushthe water line for at least 2 minutes.6. Place a sterilized insert into the Handpiece and set theWater Control knob and Power Control knob to yourpreferred operating position.Between Patients:1. Remove ultrasonic insert used, clean and sterilize.2. Disinfect the surfaces of the cabinet, Power Cord,Handpiece and cable assembly and Foot Control andcable assembly by applying an approved non-immersiontype disinfectant solution* carefully following theinstructions provided by the disinfectant solutionmanufacturer. To clean system, generously spraydisinfectant solution on a clean towel and wipe allsurfaces. Discard used towel. To disinfect system,generously spray disinfectant on a clean towel andwipe all surfaces. Allow disinfectant solution to airdry. Never spray disinfectant solution directly on theultrasonic scaler.3. Set the power to minimum and hold the handpiece over asink or drain and flush the water line at maximum waterflow for 30 seconds.4. When ready, place a sterilized insert into the handpiece.Shut-Down Procedures at the end of the day:1. Remove ultrasonic insert used, clean and sterilize.2. Turn the System OFF.3. Disinfect the surfaces of the cabinet, Power Cord,Handpiece and cable assembly and Foot Control andcable assembly by applying an approved non-immersiontype disinfectant solution* carefully following theinstructions provided by the disinfectant solutionmanufacturer. To clean system, generously spraydisinfectant solution on a clean towel and wipe allsurfaces. Discard used towel. To disinfect system,generously spray disinfectant on a clean towel andwipe all surfaces. Allow disinfectant solution to airdry. Never spray disinfectant solution directly on theultrasonic scaler.4. Close the manual shut-off valve on the dental watersupply system.*NOTE: Water-based disinfectant solutions are preferred.Some alcohol-based disinfectant solutions may be harmfuland may discolor plastic materials.9.2 Weekly MaintenanceEnd of Week Procedures(when connected to a DualSelect TM Dispensing System).1. Follow the end of week procedures listed in theDualSelect TM Dispensing System manual.<strong>ENGLISH</strong> • 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!