MOUNTING INSTRUCTIONS MA 001E-2004At a distance of around 15mm from the cable stripping edge, the FO bundle has tobe thickened up to ca. 12mm diameter by means of sticky tape (Photo 2). Treat thecorrugated tube in the same manner about 35mm from the said edge (Photo 3), with17mm target thickness (= Inner dia of entrance element).These thickened sections shall build a plug for the resin injected later on.Photo 2 Photo 3Slide the corrugated tube over the said structure in such a way that the thickenedpart of the bundle acts as a stopper within the corrugated tube (Photo 4). Finalposition of the plug around 5-8mm within the corrugated tube (fixed by means ofresin).Photo 4 Photo 5After that, the entry sleeve has to shifted over the thickened area, then fastened to itand sealed with sticky tape ( Photo 5).Page 4/10Author: W. Moritz <strong>Draka</strong> <strong>Industrial</strong> <strong>Cable</strong> <strong>GmbH</strong> Issued: Nov. 2004