13.07.2015 Views

Units, Dimensions, and Standards INTRODUCTION

Units, Dimensions, and Standards INTRODUCTION

Units, Dimensions, and Standards INTRODUCTION

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Example 1-1A bar magnet with a 1 inch square cross section is said to have a total magnetic flux of500 maxwell. Determine the flux density in tesla.SolutionFrom Appendix 1,total flux, = (500 maxwell) × 10 8 Wb= 5µWbarea, A = (1 in.×1 in.) × (2.54×10 2 ) 2 m 2= 2.54 2 ×10 4 m 2flux density, B 5Wb= = A2 4 22.54 10m= 7.75 mTExample 1-2The normal human body temperature is given as 98.6°F. Determine the equivalentCelsius <strong>and</strong> Kelvin scale temperatures.SolutionFrom Appendix 1,F 32 98.7 32Celsius temperature = =1.8 1.8= 37°CF 32Kelvin temperature = +273.151.8= 310.15 KSTANDARDS1. Working St<strong>and</strong>ardsElectrical measurement st<strong>and</strong>ards are precise resistors, capacitors, inductors, voltagesources, <strong>and</strong> current sources, which can be used for comparison purposes when measuringelectrical quantities. For example, resistance can be accurately measured by means of aWheatstone bridge which uses a st<strong>and</strong>ard resistor. Similarly, st<strong>and</strong>ard capacitors <strong>and</strong> inductorscan be employed in bridge (or other) methods to accurately measure capacitance <strong>and</strong> inductance.The st<strong>and</strong>ard resistors, capacitors, <strong>and</strong> inductors usually found in an electronicslaboratory are classified as working st<strong>and</strong>ards. Working st<strong>and</strong>ard resistors are normallyconstructed of manganin or a similar material, which has a very low temperature coefficient.They are available in resistance values ranging from 0.01 to 1 M, with typical accuracies of±0.01% to ±0.1%. A working st<strong>and</strong>ard capacitor might be air dielectric type, or might beconstructed of silvered mica. Available capacitance values are 0.001 µF to 1 µF with a typicalaccuracy of ±0.02%.St<strong>and</strong>ard inductors are available in values ranging from 100 µH to 10 H with typicalaccuracies of ±0.1%. Calibrators provide st<strong>and</strong>ard voltages <strong>and</strong> currents for calibratingvoltmeters <strong>and</strong> ammeters.7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!