R89Error code18EError code21E10 Error code29E1. Compressor discharge temperaturesensor faulty or damaged.2. Compressor discharge temperaturesensor connector (plug) disconnectedand/or oxidized due to damp or <strong>water</strong>.3. The controller and/or PC Board faultyor damaged.1. Ambient temperature sensor faulty ordamaged.2. Ambient temperature sensor connector(plug) disconnected and/or oxidized dueto damp or <strong>water</strong>.3. The controller and/or PC Board faultyor damaged.1. Compressor suction temperaturesensor faulty or damaged.2. Compressor suction temperaturesensor connector (plug) disconnectedand/or oxidized due to damp or <strong>water</strong>.3. The controller and/or PC Board faultyor damaged.Replace the compressor discharge temperaturesensor.Reconnect or clean compressor dischargetemperature sensor and wrap it with insulation tape.Replace the controller or PC Board.Replace the Ambient temperature sensor.Reconnect or clean Ambient temperature sensor andwrap it with insulation tape.Replace the controller or PC Board.Replace the Compressor suction temperature sensor.Reconnect or clean Compressor suction temperaturesensor and wrap it with insulation tape.Replace the controller or PC Board.3. Check whether the thermal relay is damaged, if so,replace.11The heat<strong>pump</strong> is notheating1. User's incorrect operation and/orparameter settings.a) The pooltemperature settingis set too low andthe desiredtemperature cannotbe reached.b) The differencebetween therequired pooltemperature andthe heat <strong>pump</strong>restart temperature(L2) is too big.c) Timer functionhas been set to aspecific ON andOFF time, whichdoes not allowsufficient time forthe heat <strong>pump</strong> tooperate.d) No electricalpower supply to theheat <strong>pump</strong> (nodisplay on thecontroller).Re-set the pool <strong>water</strong>temperature to the correctrange.Re-set by reducing the value ofL2.Re-set the timer.1. Check and ensure that circuitbreakers are ON.2. Test voltage on the PC BoardL/N/G Connectors.3. If power is not restored,replace cable.a) The temperaturedisplayed is morethan 45˚C.Check the pool <strong>water</strong>temperature sensor, replace iffaulty.2. Problem with controller or PC Board.b) PC Board isdamaged due toburnt relays.c) PC Boardmicrocontroller chipfaulty.Check and find out the cause,find faulty relay(s) and replace.Replace the PC Board.23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!