13.07.2015 Views

Domestic-user-manual - Heat pump water Heater

Domestic-user-manual - Heat pump water Heater

Domestic-user-manual - Heat pump water Heater

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

R12 Slowincrease of<strong>water</strong>temperature131415Thecontrollerdisplays''00''No displayon thecontrollerThe fandoes notoperate16 Thecompressordoes notoperatewhile the fanis working1. Insufficient refrigerant.2. The heating capacity of the heat <strong>pump</strong>is insufficient for the size of the pool.3. Serious residues/dirt occurred on theheat exchanger.4. The evaporator coil is dirty or jammedand this will affect the heat exchangeefficiency.1. Check for leakages, if found, repair and re-chargerefrigerant as per volume specification on label.2. If no leakage was found, re-charge refrigerant asper volume specification on label.Increase the size or number of heat <strong>pump</strong> units.Clean the heat exchangers.Clean the evaporator coil.5. Poor design of insulation for the pool. It is recommended to use a pool insulation cover.6. The length of the pipes is too longand/or improperly insulated.1. The controller cable damaged ordisconnected.1. Mains power supply is abnormal.1. If the length of the pipes cannot be done, ensurewell insulated piping.2. Increase the size and number of heat <strong>pump</strong> units.Reconnect or replace controller cable and wrap it withinsulation tape.2. PC board damaged. Replace PC Board.3. Pool temperature sensor and/or cabledisconnected or damaged.Reconnect or replace pool temperature sensor andwrap it with insulation tape.a) The main power supply Reconnect or replacecables is disconnected or the mains power supplydamaged.cable.b) The main power supplyvoltage is lower than 175V.Check and ensure thatthe mains power supplycable', length andthickness, is within thespecifications, if notreplace with thickercable to ensure lessvoltage drop.2. PC board power cable is disconnectedor the fuse is burnt.Reconnect PC Board cable or replace the fuse.3. PC Board transformer is damaged. Replace the PC Board transformer.4. The controller cable damaged ordisconnected.Reconnect or replace controller cable and wrap it withinsulation tape.5. PC Board damaged. Replace the PC board.1. Fan motor capacitor damaged (underthis circumstance the fan motor will Replace fan motor capacitor.overheat).2. The motor windings has been burnt. Repair or replace the fan motor.3. The display is ON but heat <strong>pump</strong> unitis not in running mode/ON.Press the power button and turn On the heat <strong>pump</strong>unit.4. Fan motor relay damaged. Check and replace if damaged.5. No fan motor output from PC Board. Replace PC board.6. Fan motor cable disconnected ordamaged.1. Compressor damaged (under thiscircumstance the compressor motor willoverheat).Reconnect or replace fan motor cable.Replace compressor capacitor.2. Compressor connecting cable is burnt. Replace compressor connecting cable.3. The compressor windings have beenburnt.Repair or replace the compressor.4. The compressor is jammed or blocked. Repair or replace the compressor.5. AC contactor does not work. a) The AC contactorwinding is damaged orthe contactor isjammed and cannotclose.Replace the AC contactor.24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!