5.75.7 FASTENING PROCEDURE<strong>PROFILE</strong> 3® roofing sheets should be drilled when fasteners are to be introduced. The fixing holes shouldbe 2mm larger in diameter than the fixing nail and should be located centrally on the timber purlins; forhook bolts or similar the hole should be located 4mm upslope from the back edge of the purlin. In all casessealant washers and felt should be utilized to ensure adequate weather protection.fig. 5.9aFixing (wrong way)fig. 5.9bFixing (wrong way)never make the holes for the fixing points with hammer and nailfig. 5.9aFixing (right way)Min 50mm30®<strong>PROFILE</strong> 3 MANUAL