INTENDED METHODS OF CONNECTION<strong>BJM</strong> <strong>Pumps</strong> has been evaluated for use with water or water based solutions. Pleasecontact the manufacturer for additional information.THREE PHASE WIRING INSTRUCTIONFOR YOUR PROTECTION, ALWAYS DISCONNECT PUMPFROM ITS POWER SOURCE BEFORE HANDLING.“Risk of electrical shock” Do not remove power supply cord andstrain relief or connect conduit directly to the pump.Installation and checking of electrical circuits and hardware shouldbe performed by a qualified licensed electrician.To automatically operate a non-automatic three phase pump, a control panel isrequired. Follow the instructions provided with the panel to wire the system for automaticthree phase pumps see automatic three phase wiring diagram.Before installing a pump, check the pump rotation to insure that wiring has beenconnected properly to power source, and that the green lead of power cord (See wiringdiagram), is connected to a valid ground, momentarily energize the pump, observing thedirections of kick back due to starting torque. Rotation is correct if kick back is in theopposite direction of rotation arrow on the pump casing. If rotation is not correct,switching of any two power leads other than ground will provide the proper rotation.9