2-wire <strong>Switches</strong><br />
Technical Data<br />
<strong>Douglas</strong> 2-wire switches are a distinctive and attractive group of<br />
products designed to satisfy practically any requirement. <strong>Switches</strong><br />
can be grouped to form compact, unobtrusive switch stations.<br />
Up to 3 switches can be fit into a single gang box. If more<br />
switches are required, use multi-gang boxes. A complete range of<br />
stock cover plates and mounting hardware is available for all sizes<br />
up to 5 gangs.<br />
Connect <strong>Douglas</strong> 2-wire switches directly to any model of <strong>Douglas</strong><br />
relay or connect to switch inputs on <strong>Douglas</strong> control devices (relay<br />
scanners, photocell override, etc.).<br />
2-wire Rocker Switch<br />
WR-8001<br />
Technical Data<br />
PART No.<br />
DESCRIPTION<br />
DIMENSIONS<br />
WR-8001<br />
Rocker Switch<br />
<br />
Rocker switch for <strong>Douglas</strong> relays and<br />
switch inputs. Press rocker to one side<br />
for ON and to other side for OFF.<br />
<br />
The WR-8001 can control up to 8 relays<br />
(Sw rating: 3A). Check wire length chart<br />
for wire runs greater than 150 feet (50m).<br />
<br />
Use WN-3700 mounting strap to install<br />
up to 3 switches into a 1 gang wall box.<br />
<br />
Rocker switch<br />
made from offwhite<br />
plastic.<br />
Black dot marks<br />
which side is to<br />
be pressed for<br />
ON.<br />
0.9<br />
1.42<br />
1.73<br />
2-wire LED Switch<br />
WR-8501, WR-8503<br />
Technical Data<br />
PART No.<br />
DESCRIPTION<br />
DIMENSIONS<br />
WR-8501<br />
1 Switch<br />
WR-8503<br />
3 Switch Module<br />
<br />
LED indicating pushbutton switch for<br />
<strong>Douglas</strong> 2-wire relays and switch<br />
inputs. Press button once for ON, press<br />
again for OFF.<br />
<br />
The WR-8501 & 03 switches control up<br />
to 4 relays. (Sw rating: 1.5A). Check<br />
wire length chart for wire runs greater<br />
than 150 feet (50m).<br />
<br />
LED's show status of the connected<br />
relay or input. Red LED indicates ON<br />
and green locator LED indicates OFF.<br />
<br />
The LED's consume 4mA of power. If a<br />
large amount of switches (>100) are<br />
connected to the same transformer,<br />
check transformer loading.<br />
<br />
Use WN-3700 mounting strap to install<br />
up to 3 WR-8501 switches into a 1<br />
gang wall box.<br />
A mounting strap is built into the WR-<br />
8503 and a WN-3700 is not required.<br />
<br />
All 3 switches<br />
of the WR-<br />
8503 obtain<br />
the input<br />
power from a<br />
common<br />
terminal.<br />
White<br />
Red 1<br />
Red 2<br />
Red 3<br />
WR-8503 Common<br />
Connection for Power<br />
<br />
Switch made from off-white plastic.<br />
1.42<br />
Plastic cap &<br />
Paper label.<br />
1.46<br />
2.72<br />
1.73<br />
1.1<br />
0.9<br />
3.98<br />
4.40<br />
Components 3.1<br />
A-3.1,2,3,4 <strong>Switches</strong><br />
www.<strong>Douglas</strong><strong>Lighting</strong><strong>Control</strong>s.com
2-wire Specialty <strong>Switches</strong><br />
Technical Data<br />
Connect 2-wire specialty switches directly to any model of <strong>Douglas</strong> 2-wire relay or connect to<br />
switch inputs on <strong>Douglas</strong> control devices (relay scanners, photocell override, etc.).<br />
If your application requires a specialized switch that is not shown, please contact <strong>Douglas</strong> and<br />
describe your requirement.<br />
2-wire Key Operated Switch<br />
WRK-8201<br />
Technical Data<br />
PART No.<br />
WRK-8201<br />
Key Switch<br />
DESCRIPTION<br />
<br />
Key switch for <strong>Douglas</strong> relays and<br />
switch inputs. Turn key to one side for<br />
ON and to other side for OFF.<br />
<br />
The WRK-8201 can control up to 4<br />
relays (Sw rating: 1.5A). Check wire<br />
length chart for wire runs greater than<br />
150 feet (50m).<br />
<br />
The key switch has an LED indicator to<br />
show the status of the connected relay<br />
or input. Red LED indicates ON and<br />
green locator LED indicates OFF.<br />
<br />
Use WN-3700 mounting strap to install<br />
up to 3 key sws into a 1 gang wall box.<br />
DIMENSIONS<br />
<br />
Key switch made from nickel tumbler<br />
mechanism mounted into an off-white<br />
plastic frame.<br />
1.42<br />
1.73<br />
0.9<br />
2-wire Vandal Proof Switch<br />
PART No.<br />
WR-8321<br />
Vandal Proof<br />
Switch<br />
WN-8331<br />
Stainless Steel<br />
Cover Plate<br />
with 3/4" hole.<br />
DESCRIPTION<br />
WR-8321<br />
<br />
Vandal proof switch button for <strong>Douglas</strong><br />
2-wire relays and switch inputs. Press<br />
button once to turn ON, press again for<br />
OFF.<br />
<br />
The WR-8321 can control up to 4 relays<br />
(Sw rating 1.5A). Check wire length<br />
chart for wire runs greater than 150' (50m).<br />
<br />
The vandal proof switch button mounts<br />
through a 3/4" hole. Install switch into<br />
consoles or mount to WN-8331 switch<br />
plate. Switch plate is fastened to the<br />
wall box with torx screws supplied.<br />
<br />
Weatherproof: suitable for outdoor<br />
applications.<br />
DIMENSIONS<br />
Technical Data<br />
<br />
The WR-8321 switch is made for<br />
stainless steel and is designed for high<br />
impact applications. It has no sharp<br />
edges and is intended for application in<br />
correctional (prison) institutions.<br />
0.75<br />
Mounting<br />
Nut<br />
1.73<br />
1.00<br />
2-wire Foot Operated Switch<br />
PART No.<br />
WR-8301<br />
Foot Switch<br />
DESCRIPTION<br />
WR-8301<br />
<br />
Foot operated switch for <strong>Douglas</strong> 2-<br />
wire relays and switch inputs. Press<br />
pedal once for ON, press again for OFF.<br />
<br />
The WR-8301 can control up to 4<br />
relays (Sw rating 1.5A). Check wire<br />
length chart for wire runs greater than<br />
150' (50m).<br />
<br />
The WR-8301 weighs 3 lbs and can be<br />
bolted to the floor if desired. Common<br />
application is for X-ray rooms. Wall<br />
switches can be connected in parallel.<br />
DIMENSIONS<br />
Technical Data<br />
<br />
The foot switch made from cast iron<br />
and is supplied with a 10' cable.<br />
<br />
There is no connector supplied with the<br />
cable. Cable diameter is 3/8" and the<br />
wire is 14 ga. stranded.<br />
10" long<br />
0.38" dia.<br />
4.28"<br />
2.87"<br />
1.87"<br />
Components 3.2<br />
A-3.1,2,3,4 <strong>Switches</strong><br />
www.<strong>Douglas</strong><strong>Lighting</strong><strong>Control</strong>s.com
Lock-out & Contact <strong>Switches</strong> (Non 2-wire)<br />
Technical Data<br />
Switch Station Lock-out Switch<br />
Lock-out switches are used to activate/deactivate <strong>Douglas</strong> switch stations to prevent unauthorized use.<br />
PART No.<br />
WRK-8292<br />
560 9<br />
Switch shown in<br />
lockout position.<br />
DESCRIPTION<br />
WRK-8292<br />
<br />
Use to lock out entire <strong>Douglas</strong> Switch<br />
Station by restricting power to station.<br />
Station can have a maximum of 8<br />
<strong>Douglas</strong> 2-wire relay switches.<br />
■<br />
Do not connect direct to <strong>Douglas</strong> 2-wire<br />
relays. Only use to control power to<br />
<strong>Douglas</strong> 2-wire switch stations.<br />
<br />
Key switch mounts with WN-3700 strap.<br />
DIMENSIONS<br />
Technical Data<br />
<br />
Key switch made from nickel tumbler<br />
mechanism mounted into an off-white<br />
plastic frame.<br />
1.42<br />
1.73<br />
0.9<br />
Momentary Switch<br />
Contact switches are not to be used to control <strong>Douglas</strong> relays directly.<br />
Use contact switches to signal other devices and/or systems.<br />
PART No.<br />
WR-8911<br />
Momentary<br />
Contact<br />
DESCRIPTION<br />
WR-8911<br />
<br />
Push button momentary contact switch.<br />
Press to close contact, release to open.<br />
<br />
Each switch is rated for 24V / 1.5A. Do<br />
not connect to <strong>Douglas</strong> 2-wire relays.<br />
Connect to MC-600 contact inputs or<br />
use to signal other systems or devices.<br />
<br />
Use WN-3700 mounting strap to install<br />
up to 3 switches into a 1-gang wall box.<br />
DIMENSIONS<br />
Technical Data<br />
<br />
Switch made from off-white plastic.<br />
1.42<br />
Plastic<br />
cap & 1.73<br />
Paper label.<br />
0.9<br />
Maintained Switch<br />
PART No.<br />
WN-5002<br />
WN-5062<br />
COM<br />
Maintained<br />
Form C<br />
Contacts<br />
NC<br />
NO<br />
Maintained Tumbler Key Switch<br />
PART No.<br />
WNK-8221<br />
COM<br />
NC<br />
NO<br />
Maintained<br />
Form C Contacts<br />
Momentary Tumbler Key Switch<br />
PART No.<br />
WNK-8231<br />
Momentary<br />
Contact<br />
NC<br />
NO<br />
WN-5002, WN-5062<br />
DESCRIPTION<br />
<br />
Maintained rocker switch.<br />
<br />
Each switch is rated for 24V / 1.5A. Do<br />
not connect to <strong>Douglas</strong> 2-wire relays.<br />
Use to signal other systems or devices.<br />
<br />
Use WN-3700 mounting strap to install<br />
up to 3 switches into a 1-gang wall box.<br />
<br />
WN-5002 and WN-5062 switches are<br />
identical except that WN-5062 has<br />
plastic cap and label.<br />
DESCRIPTION<br />
WNK-8221<br />
<br />
Maintained tumbler key switch.<br />
<br />
The WNK-8221 is rated for 24V / 1.5A.<br />
Do not connect to <strong>Douglas</strong> 2-wire relays.<br />
Use to signal other systems and devices.<br />
<br />
Use WN-3700 mounting strap to install<br />
up to 3 switches into a 1 gang wall box.<br />
DESCRIPTION<br />
WNK-8231<br />
<br />
Momentary tumbler key switch.<br />
<br />
The WNK-8231 is rated for 24V / 1.5A.<br />
Do not connect to <strong>Douglas</strong> 2-wire relays.<br />
Use to signal other systems and devices.<br />
<br />
Use WN-3700 mounting strap to install<br />
up to 3 switches into a 1 gang wall box.<br />
DIMENSIONS<br />
<br />
<strong>Switches</strong> made<br />
from off-white<br />
plastic.<br />
Technical Data<br />
Plastic cap<br />
and Label<br />
(WN-5062 only)<br />
DIMENSIONS<br />
0.9<br />
1.42<br />
Technical Data<br />
<br />
Key switch made from nickel tumbler<br />
mechanism mounted into an off-white<br />
plastic frame.<br />
1.42<br />
DIMENSIONS<br />
1.73<br />
0.9<br />
Technical Data<br />
<br />
Key switch made from nickel tumbler<br />
mechanism mounted into an off-white<br />
plastic frame.<br />
1.42<br />
1.73<br />
0.9<br />
Components 3.3<br />
A-3.1,2,3,4 <strong>Switches</strong><br />
www.<strong>Douglas</strong><strong>Lighting</strong><strong>Control</strong>s.com
2-wire Switching<br />
Technical Data<br />
2-WIRE SWITCHING TECHNOLOGY<br />
<strong>Douglas</strong> 2-wire switches are momentary switches that use internal<br />
diodes to provide an ON or OFF pulse. To the white terminal of a<br />
2-wire switch connect the 24VAC source. Connect the red<br />
terminal of a 2-wire switch to the relay.<br />
All of the switches can be serviced by the same 24VAC source<br />
(white). Therefore, a 6 switch station will require 7 wires; 1<br />
common and 6 red signal wires.<br />
<strong>Switches</strong> that have LED indicators do not require any additional<br />
wiring. The red signal wire is also used to indicate the state of the<br />
relay or control device to the switch.<br />
Lights<br />
H<br />
Breaker<br />
Transformer<br />
24VAC<br />
W<br />
B<br />
Relay<br />
Relay Panel<br />
Common<br />
Connections<br />
Switching from<br />
many Locations<br />
Sw<br />
Sw<br />
Manual<br />
Lever<br />
Internal Circuit Details<br />
2-wire Relay / 2-wire Switch<br />
Transformer<br />
24VAC<br />
W<br />
B<br />
Blue<br />
White<br />
2-wire Switch<br />
Switch<br />
Sw<br />
Switching<br />
Large Loads<br />
Sw<br />
Switching from<br />
a Distance<br />
Red<br />
Latch to lock relay ON<br />
or OFF (actually done<br />
with magnetics)<br />
2-wire<br />
Relay<br />
Gate Diodes<br />
Relay Coil<br />
<strong>Control</strong> Diodes<br />
Relays<br />
Relay<br />
Scanner<br />
Sw<br />
Switching<br />
<strong>Control</strong> Devices<br />
(Group Switching)<br />
Sw<br />
WIRE DISTANCE CHART<br />
Switching<br />
Individual Loads<br />
Sw<br />
Lights<br />
H<br />
Breaker<br />
Transformer<br />
24VAC<br />
W<br />
B<br />
Relays<br />
White<br />
Blue<br />
Red<br />
Sw<br />
W<br />
B<br />
Sw<br />
Combining <strong>Switches</strong> with<br />
an Occupancy Detector<br />
One-way Measurement<br />
Number of Relays<br />
per Switch<br />
1.5A & 3.0A rated switches<br />
(WR-8001, WR-8501, WR-8503)<br />
1<br />
2<br />
3<br />
Wire Length<br />
One way measure<br />
in feet (meters)<br />
2000 (600)<br />
1500 (450)<br />
1000 (300)<br />
Wire Gauge<br />
American<br />
Wire Gauge<br />
18 AWG<br />
18 AWG<br />
18 AWG<br />
Sw<br />
Sw<br />
Sw<br />
Sw<br />
3.0 A rated switches<br />
(WR-8001, WRK-8201)<br />
4<br />
6<br />
8<br />
500 (150)<br />
300 (90)<br />
160 (50)<br />
18 AWG<br />
18 AWG<br />
18 AWG<br />
W<br />
B<br />
Daylight Sensor<br />
Switch<br />
Components 3.4<br />
A-3.1,2,3,4 <strong>Switches</strong><br />
www.<strong>Douglas</strong><strong>Lighting</strong><strong>Control</strong>s.com