31.08.2015 Views

BACnet Node for Douglas Scanner WBI-2671 Technical Data nonvibrating

WBI-2671 - cut sheet - 1 of 2 - Douglas Lighting Control

WBI-2671 - cut sheet - 1 of 2 - Douglas Lighting Control

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OPTIONS PROGRAM<br />

MODE<br />

NORMAL<br />

MODE<br />

SELECT<br />

MASTER<br />

SWITCH<br />

ON<br />

OVERRIDE<br />

OFF<br />

OVERRIDE<br />

<strong>BACnet</strong> ® <strong>Node</strong> <strong>for</strong> <strong>Douglas</strong> <strong>Scanner</strong><br />

<strong>WBI</strong>-<strong>2671</strong><br />

<strong>Technical</strong> <strong>Data</strong><br />

PART No.<br />

<strong>WBI</strong>-<strong>2671</strong><br />

DESCRIPTION<br />

The <strong>WBI</strong>-<strong>2671</strong> is a <strong>BACnet</strong> MSTP device<br />

that allows <strong>Douglas</strong> WRS-2224 Relay<br />

<strong>Scanner</strong>s to send and receive <strong>BACnet</strong><br />

commands to or from a BAS.<br />

The <strong>WBI</strong>-<strong>2671</strong> <strong>Node</strong> uses RS-485<br />

networking technology that uses native<br />

<strong>BACnet</strong> MSTP protocol.<br />

Building Management Systems can<br />

configure and program from their database<br />

all of the functions inherent in the <strong>WBI</strong>-<strong>2671</strong><br />

and the WRS-2224.<br />

The <strong>WBI</strong>-<strong>2671</strong> con<strong>for</strong>ms to the open<br />

native <strong>BACnet</strong> variables <strong>for</strong> lighting.<br />

The <strong>WBI</strong>-<strong>2671</strong> allows programming,<br />

control and monitoring of 5 groups.<br />

The <strong>WBI</strong>-<strong>2671</strong> allows control and<br />

monitoring of 24 relays individually.<br />

The <strong>WBI</strong>-<strong>2671</strong> allows control and<br />

monitoring of 5 switch inputs.<br />

The <strong>WBI</strong>-<strong>2671</strong> allows programming, either<br />

from the WRS-2224 or the Network, of a 2-<br />

hour Time Out or a 5-minute Flick Warn.<br />

SPECIFICATION<br />

Power<br />

The <strong>WBI</strong>-<strong>2671</strong> <strong>Node</strong> obtains power from<br />

the host WRS-2224 Relay <strong>Scanner</strong>.<br />

CAUTION: Always disconnect 24VAC<br />

from the WRS-2224 <strong>Scanner</strong> prior to<br />

plugging/unplugging the <strong>WBI</strong>-<strong>2671</strong> unit.<br />

Wire Type & Method<br />

<strong>WBI</strong>-<strong>2671</strong> <strong>Node</strong>s are connected together<br />

using a shielded single twisted pair cable<br />

in a serial loop.<br />

Con<strong>for</strong>m to wiring specifications issued by<br />

the host Building Management System.<br />

Networking Technology Specification<br />

Network signal:<br />

RS-485 Transceiver.<br />

MSTP Protocol.<br />

100K Ohm bias (120 Ohm termination<br />

recommended).<br />

<strong>BACnet</strong> Spec 9.2.2 compliant.<br />

.Up to 32 devices per segment.<br />

Baud Rates (selectable)<br />

Relay Outputs<br />

24 output terminals<br />

(12 per side) are<br />

provided <strong>for</strong> relay control.<br />

<strong>Douglas</strong> 2-wire switches<br />

can be connected in<br />

parallel to permit<br />

individual control of a<br />

relay by a switch.<br />

Individual Output<br />

Buttons<br />

In operating mode, use<br />

buttons to switch the<br />

connected relay ON or OFF.<br />

In programming mode, use<br />

buttons to enter or remove<br />

the relay from the switch<br />

input being programmed.<br />

9,600 Baud.<br />

19,200 Baud.<br />

38,400 Baud.<br />

76,800 Baud.<br />

Environment<br />

Environment: Indoors, stationary, <strong>nonvibrating</strong>,<br />

non-corrosive atmosphere and<br />

non-condensing humidity.<br />

Ambient temp: -0° to +120°F (-15° to +50°C).<br />

Select Buttons<br />

& LED's <strong>for</strong>:<br />

1) Operating mode.<br />

2) Program mode.<br />

3) Flick Warn, Time Out<br />

and Flick Warn with<br />

Time Out options.<br />

Directions<br />

Programming<br />

directions are printed<br />

on keypad <strong>for</strong> handy<br />

user reference.<br />

Baud Rate Select<br />

Use the binary DIP switch<br />

to set the Baud Rate:<br />

-9,600 (both up)<br />

-19,200 (#1 up)<br />

-38,400 (#2 up)<br />

-76,800 (both down)<br />

CAUTION:<br />

<strong>WBI</strong>-<strong>2671</strong><br />

Disconnect 24V of WRS-2224<br />

BEFORE plug/unpluging this unit<br />

<strong>BACnet</strong> <strong>Node</strong> <strong>for</strong> WRS-2224 <strong>Scanner</strong><br />

Interface type: MSTP over RS-485<br />

- This node does not have a built-in end of the line termination resistor.<br />

Installer's responsibility to correctly terminate the RS-485 data bus.<br />

- Transmission Baud Rate is selectable, select appropriate baud rate<br />

<strong>for</strong> the system this node is installed to.<br />

- For in<strong>for</strong>mation regarding <strong>BACnet</strong> object types supported, refer to<br />

product cutsheet available at <strong>Douglas</strong> web site.<br />

V#<br />

Status LED<br />

Start-up: 2 blinks then solid <strong>for</strong> 2sec<br />

Run time: blinking = OK, solid = problem<br />

Baud Rate Setting<br />

9,600<br />

19,200<br />

38,400<br />

www.<strong>Douglas</strong>LightingControls.com<br />

76,800<br />

1 2<br />

lighting controls<br />

Transmit<br />

ON<br />

OFF<br />

32<br />

64<br />

128<br />

RS-485 Address Select<br />

Sum of switches set ON<br />

equals the unit's address<br />

RS-485-VCC Connection<br />

Receive<br />

VCC<br />

485 -<br />

1<br />

24816<br />

485 +<br />

GND<br />

Override Buttons<br />

Use ON and OFF<br />

override buttons to<br />

switch relay groups.<br />

Relay Group Select<br />

Use the Input Select button<br />

to choose the relay group<br />

input 1, 2, 3, 4 or 5.<br />

The selected input will have<br />

its indicator LED ON.<br />

Inputs are momentary or<br />

maintained <strong>Douglas</strong> switches<br />

MAC Address Select<br />

Use the binary DIP switch to<br />

set the MAC Address (0-255).<br />

<strong>Data</strong> Signal<br />

RS-485 Transceiver<br />

DIMENSIONS & MOUNTING<br />

Be sure to disconnect 24VAC from<br />

relay scanner be<strong>for</strong>e plugging or<br />

unplugging network node to scanner.<br />

Mount node to 35mm DIN rail<br />

installed in <strong>Douglas</strong> relay panel.<br />

Plan View<br />

6.5"<br />

(165)<br />

2.5"<br />

(64)<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

1<br />

3<br />

5<br />

7<br />

9<br />

11<br />

2<br />

4<br />

6<br />

8<br />

10<br />

12<br />

14<br />

16<br />

18<br />

20<br />

22<br />

24<br />

WRS-2224<br />

Relay<br />

<strong>Scanner</strong><br />

<strong>WBI</strong>-<strong>2671</strong><br />

<strong>Node</strong><br />

13<br />

15<br />

17<br />

19<br />

21<br />

23<br />

Sw<br />

Inputs<br />

4.0"<br />

(103)<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

23<br />

24<br />

W B<br />

1<br />

2<br />

3<br />

B 45<br />

B<br />

Side<br />

View<br />

1.75"<br />

(45)<br />

Interfaces 4.3<br />

C-4-3,4,5,6 -System Integration, <strong>BACnet</strong><br />

www.<strong>Douglas</strong>LightingControls.com


<strong>BACnet</strong> ® <strong>Node</strong> <strong>for</strong> <strong>Douglas</strong> <strong>Scanner</strong><br />

<strong>WBI</strong>-<strong>2671</strong><br />

<strong>Technical</strong> <strong>Data</strong><br />

EXTERNALLY CONFIGURED NETWORKS<br />

Integrated Systems<br />

<strong>Douglas</strong> Relay Panels can be incorporated into Building<br />

Management Control Systems that use <strong>BACnet</strong> technology.<br />

It is assumed that the BMS supports standard <strong>BACnet</strong> objects<br />

that can be used <strong>for</strong> lighting control.<br />

The <strong>WBI</strong>-<strong>2671</strong> <strong>Node</strong> plugs into the WRS-2224 Relay <strong>Scanner</strong><br />

and is connected to the <strong>BACnet</strong> network.<br />

Individual relay and groups status indicators are available on the<br />

keypad on the attached relay scanner.<br />

Individual relay and group momentary overrides are available on<br />

the keypad on the attached relay scanner.<br />

MAC Address and Configuration<br />

The MAC Address (0-255 address range) <strong>for</strong> each <strong>WBI</strong>-<strong>2671</strong> is set<br />

using the binary DIP switch on the <strong>WBI</strong>-<strong>2671</strong> unit.<br />

The Device ID <strong>for</strong> each <strong>WBI</strong>-<strong>2671</strong> is set using a variable accessible<br />

via the <strong>BACnet</strong> MSTP port.<br />

<strong>WBI</strong>-<strong>2671</strong> FUNCTIONS & FEATURES<br />

Activates a group (one command per group).<br />

Reads the group status (one command per group).<br />

Activates relays (one command per relay).<br />

Reads 'enhanced' group status (one command per<br />

relay: 0 = Absent, 1 = ON, 2 = OFF, 3 = Defective).<br />

Activates a group switch (changes the state, one<br />

command per switch).<br />

Reads a group switch (monitors the state, one<br />

command per switch).<br />

Reads the module status (version numbers and address).<br />

Provides remote programming of the five scanner<br />

resident groups (including Flick Warn, Time Out and<br />

Flick Warn with Timeout options).<br />

Querys programming of the five scanner resident<br />

groups (including Flick Warn, Time Out and Flick Warn<br />

with Time Out options).<br />

Provides local programming of the five scanner resident<br />

groups (by the keypad on the attached scanner).<br />

CONNECTIONS<br />

Relays<br />

<strong>Data</strong> Signal<br />

RS-485 Transceiver<br />

<strong>Node</strong>/<strong>Scanner</strong> Combo<br />

OPTIONS<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

PROGRAM<br />

MODE<br />

1<br />

3<br />

5<br />

7<br />

9<br />

11<br />

2<br />

4<br />

6<br />

8<br />

10<br />

12<br />

NORMAL<br />

MODE<br />

WRS-2224<br />

Relay<br />

<strong>Scanner</strong><br />

<strong>WBI</strong>-<strong>2671</strong><br />

<strong>Node</strong><br />

14<br />

16<br />

18<br />

20<br />

22<br />

24<br />

13<br />

15<br />

17<br />

19<br />

21<br />

23<br />

INPUT<br />

SELECT<br />

Master<br />

Inputs<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

23<br />

24<br />

W B<br />

1 23B45B<br />

ON<br />

OVERRIDE<br />

OFF<br />

OVERRIDE<br />

Trans<strong>for</strong>mer<br />

W 24VAC<br />

B<br />

Local<br />

Switches<br />

Connect directly<br />

to relays<br />

Relays<br />

Group<br />

Switch<br />

Inputs<br />

Standard<br />

<strong>Douglas</strong><br />

Switches<br />

Motion<br />

Control<br />

OBJECT TYPES<br />

This in<strong>for</strong>mation is provided <strong>for</strong> System Integrators who<br />

areconfiguring this device into an HVAC system.<br />

Object Type<br />

Multi-state input to check relay status<br />

(0 = absent, 1 = ON, 2 = OFF, 3 = defective)<br />

Multi-state input to check device status<br />

Multi-state input to check group programs<br />

Multi-state input to check input configurations<br />

Multi-state input to check to check Flick and<br />

Time Out status<br />

Binary input to monitor group status (ON or OFF)<br />

Binary input to monitor switch status (ON or OFF)<br />

Binary input to monitor Flick status<br />

(Flick ON or OFF)<br />

Multi-state output <strong>for</strong> <strong>for</strong> programming groups,<br />

switches and Flick<br />

Binary output (read/write) <strong>for</strong> individual relay<br />

control (ON or OFF)<br />

Binary output (read/write) <strong>for</strong> group control<br />

(ON or OFF)<br />

Binary output (read/write) <strong>for</strong> group status<br />

control (ON or OFF)<br />

Binary output (read/write) <strong>for</strong> Flick control<br />

(ON or OFF)<br />

Objects<br />

MI0 - MI23<br />

MI24<br />

MI25 - MI29<br />

MI30 - MI34<br />

MI35 - MI39<br />

BI0 - BI4<br />

BI5 - BI9<br />

BI10 - BI14<br />

MV0 - MV4<br />

BV0 - BV23<br />

BV24 - BV28<br />

BV29 - BV33<br />

BV34 - BV38<br />

Quantity<br />

24<br />

1<br />

5<br />

5<br />

5<br />

5<br />

5<br />

5<br />

5<br />

24<br />

5<br />

5<br />

5<br />

Interfaces 4.4<br />

C-4-3,4,5,6 -System Integration, <strong>BACnet</strong><br />

www.<strong>Douglas</strong>LightingControls.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!