<strong>LON</strong> / <strong>e2i</strong> <strong>Room</strong> <strong>Solution</strong> <strong>1.1</strong><br />
Office / Control panel without display<br />
2 <strong>switched</strong> <strong>light</strong> <strong>groups</strong><br />
2 <strong>sunblinds</strong><br />
heating<br />
cooling<br />
control panel<br />
occupancy sensor
Functions Office / Control panel without display<br />
2 <strong>switched</strong> <strong>light</strong> <strong>groups</strong><br />
2 <strong>sunblinds</strong><br />
heating<br />
cooling<br />
control panel<br />
occupancy sensor<br />
Option occupancy sensor<br />
For automatic detection of room<br />
occupation, an occupancy sensor<br />
can be used. It also measures the<br />
room brightness and provides this<br />
value to the network.<br />
www.elka.de<br />
Lighting<br />
Both <strong>light</strong> <strong>groups</strong> (window, door) are <strong>switched</strong> on and off at the room control panel.<br />
Central control (timer program, GLT, etc.) is possible.<br />
Sunblinds<br />
Both <strong>sunblinds</strong> are controlled together from the room control panel. A long depression<br />
of the key drives the sunblind into end position of the corresponding drive direction. A<br />
short depression of the key stops the sun blind and each further short depression<br />
changes the incidence of <strong>light</strong> (the slat angle). An equally valued or priority control<br />
from a central point or from a weather station is also possible.<br />
Heating and Cooling<br />
The heating and cooling system is controlled via zone valves. The room temperature<br />
is measured in the control panel and provided to the controller. The nominal temperature<br />
value can be changed via the adjusting wheel. By means of the presence key<br />
you can change between the operation modes (comfort / standby). The night reduction<br />
is activated by a central timer program. When the windows are open, the controller<br />
automatically switches to frost protection mode. If in cooling operation the dew<br />
point is reached, the controller stops.<br />
LEDs and corresponding symbols indicate the current state at the control panel.<br />
Lighting<br />
Both <strong>light</strong> <strong>groups</strong> are <strong>switched</strong> on and off by the occupancy sensor<br />
depending on the room brightness. The occupancy sensor can be<br />
overridden by the room control panel.<br />
Heating and Cooling<br />
The operation mode switch-over (comfort / standby) is effected independent<br />
of the brightness by detection of the occupancy sensor.<br />
Monitoring<br />
In addition to the evaluation of window contacts, the occupancy sensor<br />
can also be <strong>switched</strong> into the insensitive signalling mode. It then<br />
passes on its information to a central point.
The <strong>Room</strong> Control Panel is available<br />
in the designs of the companies<br />
Berker, Gira and Jung.<br />
We are pleased to show you further<br />
design variants in our catalogue.<br />
How to be made Designs<br />
+ -<br />
M<br />
<strong>light</strong><br />
heating / cooling<br />
sunblind<br />
window contact<br />
control panel<br />
dew point sensor<br />
occupancy sensor<br />
Application-Controller AC101 RLF<br />
+ -<br />
<strong>LON</strong><br />
Berker B.3 Gira E2 Jung Edelstahl<br />
� The functionality can be extended by adding<br />
max. 6 <strong>e2i</strong> modules via a low-cost local bus<br />
(without increasing the amount of nodes).<br />
� supply voltage: 230 V AC<br />
� 2 bi-stable Relay outputs μ 16 A<br />
(<strong>switched</strong> <strong>light</strong> circles)<br />
� temperature controller<br />
(combined heating and cooling)<br />
� 2 digital outputs e. g. to control a thermoelectrical<br />
valve actuator<br />
� 2 digital inputs for contacts<br />
(e. g. dew point sensor, window contact,<br />
broken glass detector)<br />
+ -<br />
<strong>e2i</strong> Sunblind module 2-fold<br />
� supply via system bus of <strong>LON</strong> Controller<br />
AC101 RLF<br />
� 2 mechanically locked outputs 6 A/230 V AC<br />
M M<br />
<strong>e2i</strong><br />
www.elka.de
Calculation<br />
1 x Application-Controller € 214.00<br />
AC101 RLF<br />
1 x Sunblind Module 2-fold € 74.00<br />
EJA 2.6 AC<br />
1 x <strong>Room</strong>-Climate-Module starting € 165.60<br />
e.g. Berker / Gira / Jung<br />
with external push-button<br />
1 x 4 fold push-button sensor (neutral position) € 26.00<br />
e. g. Berker / Gira / Jung<br />
1 x LNS node license € 10.00<br />
2 x electricalthermal valve drive starting € 40.00<br />
<strong>LON</strong> router starting € 8.00<br />
proportionately<br />
Total costs per room starting € 537.60<br />
Costs per room, inclusive option starting € 646.60<br />
Option occupancy sensor<br />
1 x <strong>e2i</strong> Occupancy Sensor € 109.00<br />
<strong>e2i</strong>.PIR-K 360.5<br />
Resulting costs for window contacts, dew point sensors, system integration and<br />
installation are not considered in this calculation. The specified prices are standard<br />
prices and can deviate.<br />
The indicated prices refer to the price list 2008/2009 of ELKA-Elektronik GmbH. Our<br />
prices are calculated ex works.<br />
Subject to change without notice.<br />
www.elka.de<br />
Download<br />
Use our online service. On www.elka.de<br />
technical data and advertisement texts of<br />
our products are available for download.<br />
ELKA-Elektronik GmbH<br />
Hohe Steinert 10<br />
D-58509 Lüdenscheid<br />
Telephone +49 (0) 2351 176-1860<br />
Telefax +49 (0) 2351 176-1780<br />
sales@elka.de<br />
www.elka.de<br />
Occupancy and sunblind control fulfill important<br />
criteria for the evaluation of the energy efficiency<br />
class according to DIN V 18599.<br />
The energy-saving potential is increased by<br />
individual room regulation with monitoring of<br />
the window contacts.<br />
© 2008 ELKA-Elektronik GmbH Planning document “<strong>Room</strong> <strong>Solution</strong> <strong>1.1</strong>” release 04/2008