<strong>LON</strong> / <strong>e2i</strong> <strong>Room</strong> <strong>Solution</strong> <strong>1.1</strong><br />

Office / Control panel without display<br />

2 <strong>switched</strong> <strong>light</strong> <strong>groups</strong><br />

2 <strong>sunblinds</strong><br />

heating<br />

cooling<br />

control panel<br />

occupancy sensor


Functions Office / Control panel without display<br />

2 <strong>switched</strong> <strong>light</strong> <strong>groups</strong><br />

2 <strong>sunblinds</strong><br />

heating<br />

cooling<br />

control panel<br />

occupancy sensor<br />

Option occupancy sensor<br />

For automatic detection of room<br />

occupation, an occupancy sensor<br />

can be used. It also measures the<br />

room brightness and provides this<br />

value to the network.<br />

www.elka.de<br />

Lighting<br />

Both <strong>light</strong> <strong>groups</strong> (window, door) are <strong>switched</strong> on and off at the room control panel.<br />

Central control (timer program, GLT, etc.) is possible.<br />

Sunblinds<br />

Both <strong>sunblinds</strong> are controlled together from the room control panel. A long depression<br />

of the key drives the sunblind into end position of the corresponding drive direction. A<br />

short depression of the key stops the sun blind and each further short depression<br />

changes the incidence of <strong>light</strong> (the slat angle). An equally valued or priority control<br />

from a central point or from a weather station is also possible.<br />

Heating and Cooling<br />

The heating and cooling system is controlled via zone valves. The room temperature<br />

is measured in the control panel and provided to the controller. The nominal temperature<br />

value can be changed via the adjusting wheel. By means of the presence key<br />

you can change between the operation modes (comfort / standby). The night reduction<br />

is activated by a central timer program. When the windows are open, the controller<br />

automatically switches to frost protection mode. If in cooling operation the dew<br />

point is reached, the controller stops.<br />

LEDs and corresponding symbols indicate the current state at the control panel.<br />

Lighting<br />

Both <strong>light</strong> <strong>groups</strong> are <strong>switched</strong> on and off by the occupancy sensor<br />

depending on the room brightness. The occupancy sensor can be<br />

overridden by the room control panel.<br />

Heating and Cooling<br />

The operation mode switch-over (comfort / standby) is effected independent<br />

of the brightness by detection of the occupancy sensor.<br />

Monitoring<br />

In addition to the evaluation of window contacts, the occupancy sensor<br />

can also be <strong>switched</strong> into the insensitive signalling mode. It then<br />

passes on its information to a central point.


The <strong>Room</strong> Control Panel is available<br />

in the designs of the companies<br />

Berker, Gira and Jung.<br />

We are pleased to show you further<br />

design variants in our catalogue.<br />

How to be made Designs<br />

+ -<br />

M<br />

<strong>light</strong><br />

heating / cooling<br />

sunblind<br />

window contact<br />

control panel<br />

dew point sensor<br />

occupancy sensor<br />

Application-Controller AC101 RLF<br />

+ -<br />

<strong>LON</strong><br />

Berker B.3 Gira E2 Jung Edelstahl<br />

� The functionality can be extended by adding<br />

max. 6 <strong>e2i</strong> modules via a low-cost local bus<br />

(without increasing the amount of nodes).<br />

� supply voltage: 230 V AC<br />

� 2 bi-stable Relay outputs μ 16 A<br />

(<strong>switched</strong> <strong>light</strong> circles)<br />

� temperature controller<br />

(combined heating and cooling)<br />

� 2 digital outputs e. g. to control a thermoelectrical<br />

valve actuator<br />

� 2 digital inputs for contacts<br />

(e. g. dew point sensor, window contact,<br />

broken glass detector)<br />

+ -<br />

<strong>e2i</strong> Sunblind module 2-fold<br />

� supply via system bus of <strong>LON</strong> Controller<br />

AC101 RLF<br />

� 2 mechanically locked outputs 6 A/230 V AC<br />

M M<br />

<strong>e2i</strong><br />

www.elka.de


Calculation<br />

1 x Application-Controller € 214.00<br />

AC101 RLF<br />

1 x Sunblind Module 2-fold € 74.00<br />

EJA 2.6 AC<br />

1 x <strong>Room</strong>-Climate-Module starting € 165.60<br />

e.g. Berker / Gira / Jung<br />

with external push-button<br />

1 x 4 fold push-button sensor (neutral position) € 26.00<br />

e. g. Berker / Gira / Jung<br />

1 x LNS node license € 10.00<br />

2 x electricalthermal valve drive starting € 40.00<br />

<strong>LON</strong> router starting € 8.00<br />

proportionately<br />

Total costs per room starting € 537.60<br />

Costs per room, inclusive option starting € 646.60<br />

Option occupancy sensor<br />

1 x <strong>e2i</strong> Occupancy Sensor € 109.00<br />

<strong>e2i</strong>.PIR-K 360.5<br />

Resulting costs for window contacts, dew point sensors, system integration and<br />

installation are not considered in this calculation. The specified prices are standard<br />

prices and can deviate.<br />

The indicated prices refer to the price list 2008/2009 of ELKA-Elektronik GmbH. Our<br />

prices are calculated ex works.<br />

Subject to change without notice.<br />

www.elka.de<br />

Download<br />

Use our online service. On www.elka.de<br />

technical data and advertisement texts of<br />

our products are available for download.<br />

ELKA-Elektronik GmbH<br />

Hohe Steinert 10<br />

D-58509 Lüdenscheid<br />

Telephone +49 (0) 2351 176-1860<br />

Telefax +49 (0) 2351 176-1780<br />

sales@elka.de<br />

www.elka.de<br />

Occupancy and sunblind control fulfill important<br />

criteria for the evaluation of the energy efficiency<br />

class according to DIN V 18599.<br />

The energy-saving potential is increased by<br />

individual room regulation with monitoring of<br />

the window contacts.<br />

© 2008 ELKA-Elektronik GmbH Planning document “<strong>Room</strong> <strong>Solution</strong> <strong>1.1</strong>” release 04/2008