Grind flush<br />

Typical<br />

45º<br />

75 mm (3 in.) typical<br />

Section A-A, Typical<br />

A<br />

A<br />

125 mm (5 in.)<br />

typical<br />

Typical<br />

Neck 6 mm ( 1 / 4 in.) thick min.<br />

1800 mm<br />

(6 ft) max<br />

B<br />

Except for handles, cover<br />

plate not shown.<br />

B<br />

16 mm ( 5 / 8 in.) diameter rod,<br />

4 places<br />

900 mm (3 ft) max<br />

1.5 mm ( 1 / 16 in.) thick gasket<br />

Cover 5 mm ( 3 150 mm<br />

/ 16 in.) thick minimum<br />

(6 in.)<br />

5 mm ( 3 / 16 in.) galv. wirerope lanyard<br />

250 mm<br />

(10 in.) max<br />

Note 1<br />

75 mm<br />

(3 in.)<br />

Note 3<br />

5 mm ( 3 / 16 in.) typical 100 mm (4 in.) minimum<br />

75 mm (3 in.) x 10 mm ( 3 / 8 in.)<br />

bar flange<br />

Roof plate<br />

6 mm ( 1 / 4 in.) reinforcing plate, when required. See Note 4.<br />

38 mm (1.5 in.) x 38 mm (1.5 in.) x 6 mm ( 1 / 4 in.) tab<br />

Section B-B<br />

Notes:<br />

1. Weld size shall be the smaller of the plate thicknesses being joined.<br />

• 2. Cover may be either parallel to roof or horizontal. Opening may be oriented as desired.<br />

3. Bolts shall be 16-mm ( 5 / 8 -in.) diameter in 20-mm ( 3 / 4 -in.) holes, which shall be equally spaced and shall not exceed 125-mm (5 in.) on center.<br />

4. When required, provide 6-mm ( 1 / 4 -in.) reinforcing plate. Width at least 1 / 2 smallest opening dimension. Round outside corners with 75 mm<br />

(3 in.) radius, minimum. Seams shall be square groove butt-welded.<br />

Figure 5.17—Rectangular Roof Openings with Flanged Covers