Accessories<br />
l-56 Electr ical Interlock<br />
Description<br />
L-56 electrical interlocks are designed to be<br />
used as auxiliary control contacts for West<br />
inghouse A/200 contactors. One interlock<br />
fits all sizes from 00-4. Because the L-56<br />
mounts within the outside dimension of the<br />
contactor, four interlocks per contactor can<br />
be added without any increase in panel area.<br />
The L-56 is held in position by two attached<br />
spring clips so no mounting hardware or<br />
tools are required. For easy wiring, inter<br />
locks are designed to mount in either of two<br />
90' positions, whichever is more convenient<br />
to the user. See illustration.<br />
Mounting Positions and Number<br />
Interlocks may be mounted as indicated by black squares.<br />
Non-reversing Starters and Contactors<br />
Sizes 00, ° and 1<br />
Sizes 00, ° and 1<br />
1, 2, 3 Pole<br />
4, 5 Pole<br />
Sizes 2, 2 and 4<br />
2, 3, 4, 5 Pole<br />
C D<br />
Reversi ng, Two -Speed and Mechanically<br />
Interlocked Contactors<br />
All Sizes All Sizes<br />
Horizontal Vertical<br />
list Prices Discount C1 0-S5<br />
Catalog<br />
Number<br />
L-56<br />
L-56B<br />
L-56C<br />
L-56D<br />
L-56E<br />
L-56F<br />
L-56G<br />
L-56M<br />
Type Contacts<br />
1 NO, 1 NC<br />
2NO<br />
2NC<br />
lNO<br />
lNC<br />
1 NO Early Make, 1 NO<br />
1 NC Delayed Break, 1 NO<br />
1 NC Delayed Break, plus 1 NC<br />
Switching Ratings<br />
List<br />
Price<br />
$12.00<br />
16.00<br />
16.00<br />
12,00<br />
12.00<br />
16.00<br />
16.00<br />
16.00<br />
Load Voltage Current (Amperes)<br />
� ... -�� ... - -<br />
Inrush Normal<br />
Inductive, Ac 110-125 30 3<br />
220-250 15 1.5<br />
440-480 7,5 .75<br />
550-600 6 .6<br />
Dc 115-125 1.1<br />
230-250<br />
.55<br />
550-600 .2<br />
Contln-.lous current carryiqg capacity 10 amperes<br />
maximum.<br />
Mechanical Interlocks<br />
Horizontal<br />
Design<br />
Description<br />
The mechanical interlock for A/200 devices<br />
is a self contained unit either factory assembled<br />
on complete reversing or multispeed<br />
devices or is available in kit form for<br />
field mounting, The mechanical interlock is<br />
a lever type mechanism which prevents any<br />
closing motion of one member of a reversing<br />
or multi-speed contactor or motor controller,<br />
until the opposing member is essentially<br />
completely open.<br />
list Prices Discount C1 0-S5<br />
Contactor Arrangement Interlock Cant.<br />
(No. of<br />
Horiz. or<br />
Cat. No. Size<br />
3X3 Horizontal M-33-1 A 0, 1<br />
4X4 Horizontal M-33-1A 0, 1<br />
5X3 Horizontal M-33-1A 0, 1<br />
All Pole Cob" Vert. M-34-1 0, 1<br />
3X3 Vert. Rev. M-33-2A 2<br />
3X3 Vert. Rev. M-34-2 2<br />
5X3 Horizontal M-35-2 2<br />
4X4 Horizontal M-36-2 2<br />
All Pole Comb, Horiz. M-33-3A 3, 4<br />
All Pole Comb. Vert. M-34-3 3, 4<br />
@ Cannot be mounted i n thi s position on Size 2<br />
contactors and starters .<br />
list<br />
Price<br />
$1 2<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
20<br />
20<br />
8220 C WEA<br />
Catalog Section<br />
Page 19<br />
Time Delay Interlock<br />
The Westi nghouse solid state time delay<br />
interlock provides accurate, re liable timing<br />
in a minimum of panel space. Field mountable<br />
in the interlock cavity of A/200 starters and<br />
contactors, it has one NO contact. Designed<br />
to switch a 120 volt Ac coil. it may be wired<br />
in series with the starter or contactor coil. It<br />
is also available with a mounting plate for<br />
panel use.<br />
list Prices Discount C1 0-S5<br />
Number<br />
Starter or Contactor Mounting<br />
On Delay TON-56<br />
Off Delay TOF-56<br />
Panel Mounting<br />
On Delay TO N-56P<br />
Off Delay TOF-56P<br />
Ratings<br />
Time Delay Range: 0.2 to 30 seconds.<br />
Power Requirement: 2 VA<br />
list Price<br />
$72<br />
72<br />
Power Rating: Sufficient to drive sizes 00-4<br />
contactors (ex. 4, 5 pole, sizes 3, 4).<br />
Voltage Rating: 120 Ac, +10% @ 50-60 Hz.<br />
Solid State Contacts: 0.5 amps inductive<br />
load (5.8 amps max. inrush)<br />
Recycling Speed: 150 operations per<br />
minute, max.<br />
78<br />
78<br />
Ambient Temp, Range: -20·C to 60·C.<br />
Repeat.: ± 2% with voltage variation ± 10%.<br />
Reset Time On Delay: 8 ms. after time out,<br />
2 seconds before time out.<br />
Min, Energ _ Time Off Delay: 0.1 seconds.<br />
Mounting Positions (see drawing).<br />
Starters: Two top positions only.<br />
Contactors: All positions<br />
Interlock Must be<br />
Mounted as Indicated<br />
www . <strong>Electrical</strong><strong>Part</strong><strong>Manuals</strong> . com