SESSION 22<br />

Wednesday February 3 rd , 1:30 PM<br />

Systems and Instruments for Human-Machine Interfaces<br />

Session Chair: Long Yan, Samsung Electronics, Hwaseong, Korea<br />

Associate Chair: Refet Firat Yazicioglu, GlaxoSmithKline, Herent, Belgium<br />

8:30 AM<br />

22.1 Implanted Integrated Circuit Requirements For Brain - Machine<br />

Interfaces<br />

K. Shendy<br />

Stanford University, Palo Alto, CA<br />

9:00 AM<br />

22.2 A 176-Channel 0.5cm 3 0.7g Wireless Implant for Motor Function<br />

Recovery after Spinal Cord Injury<br />

Y-K. Lo, C-W. Chang, Y-C. Kuan, S. Culaclii, B. Kim, K. Chen, P. Gad, V. R. Edgerton,<br />

W. Liu<br />

University of California, Los Angeles, CA<br />

9:30 AM<br />

22.3 A 141µW Sensor SoC on OLED/OPD Substrate for SpO 2 /ExG Monitoring<br />

DS2 Sticker<br />

Y. Lee, H. Lee, J. Jang, J. Lee, M. Kim, J. Lee, H. Kim, K-R. Lee, K. Kim, H. Cho,<br />

S. Yoo, H-J. Yoo<br />

KAIST, Daejeon, Korea<br />

Break 10:00 AM<br />

10:15 AM<br />

22.4 A 172µW Compressive Sampling Photoplethysmographic Readout<br />

DS2 with Embedded Direct Heart-Rate and Variability Extraction from<br />

Compressively Sampled Data<br />

P. Venkata Rajesh 1,2 , J. M. V. Sarmiento 3 , L. Yan 1 , A. Bozkurt 3 , C. Van Hoof 1,2 ,<br />

N. Van Helleputte 1 , R. F. Yazicioglu 1 , M. Verhelst 2<br />

1<br />

imec, Leuven, Belgium; 2 KU Leuven, Leuven, Belgium<br />

3<br />

North Carolina State University, Raleigh, NC<br />

10:45 AM<br />

22.5 A 0.5V 55µW 64×2-Channel Binaural Silicon Cochlea for Event-Driven<br />

Stereo-Audio Sensing<br />

M. Yang, C-H. Chien, T. Delbruck, S-C. Liu<br />

ETH Zurich/University of Zurich, Zurich, Switzerland<br />

11:15 AM<br />

22.6 A 22V Compliant 56µW Active Charge Balancer Enabling 100%<br />

Charge Compensation even in Monophasic and 36% Amplitude<br />

Correction in Biphasic Neural Stimulators<br />

N. Butz 1 , A. Taschwer 2 , Y. Manoli 1,2,3 , M. Kuhl 1,3<br />

1<br />

University of Freiburg - IMTEK, Freiburg, Germany<br />

2<br />

Hahn-Schickard, Villingen-Schwenningen, Germany<br />

3<br />

BrainLinks-BrainTools Cluster of Excellence, Freiburg, Germany<br />

11:45 AM<br />

22.7 A 966-Electrode Neural Probe with 384 Configurable Channels in<br />

0.13µm SOI CMOS<br />

C. Mora Lopez 1 , S. Mitra 1 , J. Putzeys 1 , B. Raducanu 1,2 , M. Ballini 1 , A. Andrei 1 ,<br />

S. Severi 1 , M. Welkenhuysen 1 , C. Van Hoof 1,2 , S. Musa 1 , R. F. Yazicioglu 1<br />

1<br />

imec, Leuven, Belgium; 2 KU Leuven, Heverlee, Belgium<br />

12:00 PM<br />

22.8 Multi-Functional Microelectrode Array System Featuring 59,760<br />

Electrodes, 2048 Electrophysiology Channels, Impedance and<br />

Neurotransmitter Measurement Units<br />

V. Viswam, J. Dragas, A. Shadmani, Y. Chen, A. Stettler, J. Müller, A. Hierlemann<br />

ETH Zurich, Basel, Switzerland<br />

Conclusion 12:15 PM<br />