6. Setting ranges<br />
Light value level 1–14 (adjustable)<br />
level 1 approx. 4 klx. – low brightness<br />
level 14 over 50 klx. – bright midday sun<br />
Basic program<br />
retract level 4 approx. 15 klx.<br />
extend level 5 approx. 18 klx.<br />
Note: The light values for extending and retracting can be set<br />
differently, but the level for retracting can never be set to be<br />
greater than the level for extending<br />
Temperature value level 1 – 14 or “- -” (adjustable)<br />
level 1 approx. 17°C<br />
level 14 approx. 30°C<br />
Basic program (not temperature-controlled)<br />
Note: If shade is to be controlled as function of temperature,<br />
select the desired level instead of " – " when programming.<br />
Wind value level 1– 9 (adjustable)<br />
level 1 light breeze<br />
level 9 storm<br />
Basic program level 3<br />
Attention: If the wind value is set too high, there is a risk of the<br />
sunshade system being destroyed<br />
Delay time for level 5 – 30 (adjustable)<br />
the light value level 5 = 5 min.<br />
level 30 = 30 min.<br />
Basic program<br />
extend level 5 = 5 min.<br />
retract level 10 = 10 min.<br />
Note: the delay times for extending/retracting can be set<br />
differently.<br />
12