4.2 Plates<br />
4.2.1 General<br />
4.2.1.1 Except as otherwise provided for in 4.1, plates shall conform to one of<br />
the specifications listed in 4.2.2 through 4.2.6, subject to the modifications<br />
and limitations in this standard.<br />
4.2.1.2 Plate for shells, roofs, and bottoms may be ordered on an edgethickness<br />
basis or on a weight (kg/m 2 [lb/ft 2 ]) basis, as specified in 4.2.1.2.1,<br />
4.2.1.2.2, and 4.2.1.2.3.<br />
4.2.1.2.1 The edge thickness ordered shall not be less than the computed<br />
design thickness or the minimum permitted thickness.<br />
4.2.1.2.2 The weight ordered shall be great enough to provide an edge<br />
thickness not less than the computed design thickness or the minimum<br />
permitted thickness.<br />
4.2.1.2.3 Whether an edge-thickness or a weight basis is used, an underrun<br />
not more than 0.3 mm (0.01 in.) from the computed design thickness or the<br />
minimum permitted thickness is acceptable.<br />