26 Program description<br />
Button Read out of single load profile channels,<br />
selection leads to extension of the window.<br />
First of all read out all available channels via the button read out available channels.<br />
Then you can select the load profile channels to be read out by clicking on the<br />
checkbox. To read out the marked load profile channels click on OK.<br />
MO Menu option Log book...<br />
Read out of the operation log book from the meter<br />
Readout > Log book...<br />
Start date Setting of the start date of the log book which<br />
is to be read out, start is 24:00 o’clock<br />
End date Setting of the end date of the log book which<br />
is to be read out, end is 24:00 o’clock<br />
Read out complete Read out of the complete log book<br />
Read out identity number in additionally In addition to the log book entries, the<br />
selected meter addresses and identity<br />
numbers in the selection list are read out in<br />
order to be able to allcoate the log book<br />
entries to the meter at a later date.