Cooling down (not DW20.1)<br />
SERVICE MENU<br />
Machines with softener : Cool down step is NOT performed during regeneration.<br />
Drain pump<br />
Inlet valve<br />
Circulation pump<br />
Drain pump<br />
5 sec<br />
24 sec<br />
60 sec<br />
25 sec<br />
Pre-rinse<br />
Inlet valve<br />
170 pulse*, 14 sec, 0.9 lit<br />
Circulation pump 20 sec, Lower arm low pressure **<br />
Drain pump<br />
25 sec<br />
1st. Rinse<br />
Inlet valve<br />
605 pulse*, 47 sec, 3.1 lit***<br />
545 pulse* 43 sec, 2.8 lit**<br />
Circulation pump<br />
Circulation pump<br />
Drain pump<br />
9 min<br />
60 sec, Upper arm high pressure**<br />
2 sec SCS stage<br />
Circulation pump 20 sec SCS stage, Upper arm high pressure **<br />
Drain pump<br />
25 sec<br />
Final rinse<br />
Inlet valve<br />
605 pulse*, 47 sec, 3.1 lit***<br />
545 pulse* 43 sec, 2.8 lit**<br />
Circulation pump<br />
Circulation pump, Heater<br />
Circulation pump, Combined dispenser<br />
Circulation pump<br />
60 sec<br />
60°C Temperature stop<br />
60 sec<br />
4 min<br />
Circulation pump 50 sec, Upper arm high pressure **<br />
Pause<br />
Drain pump<br />
60 sec<br />
25 sec<br />
Drying<br />
Fan<br />
48 min<br />