Cooling down (not DW20.1)<br />

SERVICE MENU<br />

Machines with softener : Cool down step is NOT performed during regeneration.<br />

Drain pump<br />

Inlet valve<br />

Circulation pump<br />

Drain pump<br />

5 sec<br />

24 sec<br />

60 sec<br />

25 sec<br />

Pre-rinse<br />

Inlet valve<br />

170 pulse*, 14 sec, 0.9 lit<br />

Circulation pump 20 sec, Lower arm low pressure **<br />

Drain pump<br />

25 sec<br />

1st. Rinse<br />

Inlet valve<br />

605 pulse*, 47 sec, 3.1 lit***<br />

545 pulse* 43 sec, 2.8 lit**<br />

Circulation pump<br />

Circulation pump<br />

Drain pump<br />

9 min<br />

60 sec, Upper arm high pressure**<br />

2 sec SCS stage<br />

Circulation pump 20 sec SCS stage, Upper arm high pressure **<br />

Drain pump<br />

25 sec<br />

Final rinse<br />

Inlet valve<br />

605 pulse*, 47 sec, 3.1 lit***<br />

545 pulse* 43 sec, 2.8 lit**<br />

Circulation pump<br />

Circulation pump, Heater<br />

Circulation pump, Combined dispenser<br />

Circulation pump<br />

60 sec<br />

60°C Temperature stop<br />

60 sec<br />

4 min<br />

Circulation pump 50 sec, Upper arm high pressure **<br />

Pause<br />

Drain pump<br />

60 sec<br />

25 sec<br />

Drying<br />

Fan<br />

48 min<br />