15.11.2016 Views

Service%20Manual%20DW20%20EN

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

EU (not DW20.C)<br />

Normal wash and High temp selected (for machines produced from W16 2005)<br />

Pre wash<br />

Component<br />

Drain pump<br />

Inlet valve<br />

Commentary<br />

25 sec<br />

605 pulse*, 47 sec, 3.1 lit***<br />

545 pulse* 43 sec, 2.8 lit EU**<br />

Circulation pump 30 sec Upper arm high pressure**<br />

Pause<br />

1 sec<br />

Circulation pump 60 sec Upper arm high pressure**<br />

Circulation pump<br />

Drain pump<br />

30 sec**<br />

2 sec SCS stage<br />

Circulation pump 20 sec SCS stage Upper arm high pressure **<br />

Drain pump<br />

Inlet valve<br />

25 sec<br />

605 pulse*, 47 sec, 3.1 lit***<br />

545 pulse* 43 sec, 2.8 lit EU**<br />

Circulation pump, Heater<br />

Drain pump<br />

480 sec - 32°C Temperature stop<br />

2 sec SCS stage<br />

Circulation pump 20 sec SCS stage Upper arm high pressure **<br />

Drain pump<br />

25 sec<br />

Main wash<br />

Inlet valve<br />

605 pulse*, 47 sec, 3.1 lit***<br />

545 pulse* 43 sec, 2.8 lit EU**<br />

Circulation pump 60 sec Upper arm high pressure**<br />

Circulation pump, Combined dispenser<br />

Circulation pump<br />

Circulation pump, Heater<br />

Circulation pump<br />

Circulation pump<br />

Drain pump<br />

Circulation pump<br />

Drain pump<br />

3 sec<br />

3 min<br />

55°C Temperature stop<br />

20 min<br />

1 min Upper arm high pressure**<br />

2 sec SCS stage<br />

20 sec SCS stage Upper arm high pressure**<br />

25 sec<br />