<strong>Moeller</strong> <strong>Wiring</strong> <strong>Manual</strong> <strong>02</strong>/<strong>05</strong><br />

Electronic motor starters and drives<br />

Soft starters DM4<br />

Standard applications (selector switch)<br />

Labelling on<br />

device<br />

Indication on<br />

keypad<br />

Delta circuit<br />

Normally, soft starters are connected directly in<br />

series (in-line) with the motor. The DM4 soft<br />

starters also allow a delta connection.<br />

Advantage:<br />

This is a less expensive alternative since the soft<br />

starter has to deliver only 58 % of the motor’s<br />

rated current.<br />

Disadvantages over in-line connection:<br />

As in a star-delta circuit, the motor must be<br />

connected with six conductors.<br />

The DM4’s overload protection is active only in<br />

one phase, so that additional motor protection<br />

must be fitted in the parallel phase or in the<br />

supply cable.<br />

Meaning Notes<br />

Standard Standard Standard Default settings, suitable without adaptation<br />

for most applications<br />

High torque1) High Torque High breakaway<br />

torque<br />

Drives with higher friction torque at standstill<br />

Pump Pump Small pump Pump drives up to 15 kW<br />

Pump<br />

Kickstart<br />

Light<br />

conveyor<br />

Heavy<br />

conveyor<br />

Low inertia<br />

fan<br />

High inertia<br />

fan<br />

Recip<br />

compressor<br />

Screw<br />

compressor<br />

Pump.w.Kick Large pump Pump drives over 15 kW Longer deceleration<br />

times.<br />

LightConvey Light conveyor<br />

HeavyConvey Heavy-duty<br />

conveyor<br />

LowInert.fan Low-inertia fan Fan drive with relatively small mass inertia<br />

moment of up to 15 times the motor’s inertia<br />

moment<br />

HighInertfan High-inertia fan Fan drive with relatively large mass inertia<br />

moment of over 15 times the motor’s inertia<br />

moment Longer ramp-up times.<br />

RecipCompres Reciprocal<br />

compressor<br />

ScrewCompres Screw<br />

compressor<br />

Higher start pedestal, p.f. optimization<br />

matched<br />

Increased current consumption, no current<br />

limitation<br />

1) For the “High Torque” setting, the soft starter must be able to supply 1.5 times the motor’s rated current.<br />

Note:<br />

The delta connection is more cost-effective at<br />

motor ratings over 30 kW and when replacing<br />

star-delta switches.<br />