31.01.2018 Views

SA_VOL2 EMPLOYED

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1<br />

NTS<br />

4<br />

NTS<br />

ALUMINUM PV FRAMING<br />

2<br />

1 : 50<br />

5<br />

1 : 50<br />

3<br />

1 : 50<br />

Q<br />

canopy system assembly<br />

Primary rib truss위에 고정 철물을 이용하여 원형의 hoop들이 위치하고, 차례로 gutter rib & cage, gutter<br />

surface, flexible joint for pv panel, pv panel frame, pv panel, infill panel들이 위치하게 됩니다.<br />

DM Stamp<br />

MTL-321<br />

METAL WALL PANEL<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

1,100 TYP<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

5<br />

MTL-411<br />

GLS-120<br />

TEMPERED GLASS, DOUBLE LAYERED,<br />

FRIT PATTERN<br />

3,000 TYP.<br />

1,050<br />

600504<br />

Copyright by Bureau Expo Dubai 2020 (EX20). All rights reserved. This<br />

document may not, in whole or in part, be reproduced, stored, transmitted or<br />

distributed in any form or by any means, whether electronic, mechanical, by<br />

photocopy, recording or otherwise, without the prior written permission of<br />

EX20. Except where otherwise expressly agreed in writing by EX20, EX20<br />

shall have no responsibility or liability for any loss (direct, consequential or<br />

otherwise) which may arise from reliance on or use of this document or the<br />

information contained therein.<br />

DO NOT SCALE THIS DRAWING.<br />

2,500<br />

1,050<br />

N<br />

1,050<br />

MTL-320<br />

METAL FLOOR PANEL<br />

MTL-315<br />

STAINLESS STEEL TENSION RODS<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

MTL-317<br />

STAINLESS STEEL WIRE MESH<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-211<br />

AESS CATEGORY 4, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-211<br />

AESS CATEGORY 4, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-317<br />

STAINLESS STEEL WIRE MESH<br />

PATTERN DOESN'T REPRESENT ACTUAL<br />

MESH PATTERN FOR MORE INFORMATION<br />

REFER TO ARCHITECTURAL DESIGN REPORT<br />

MTL-321<br />

METAL WALL PANEL<br />

MTL-320<br />

METAL FLOOR PANEL<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

GLS-120<br />

TEMPERED GLASS, DOUBLE LAYERED,<br />

FRIT PATTERN<br />

MTL-412<br />

ALUMINUM PV INFILL PANELS<br />

3<br />

600508<br />

No<br />

Description<br />

<strong>SA</strong>FETY, HEALTH AND ENVIRONMENT INFORMATION<br />

Brief details on the identified hazard symbol referencing the unusual residual<br />

hazards / risks are listed above.<br />

PERIMETER PV AXON DETAIL<br />

PERIMETER PV PLAN DETAIL AT LOUVERS LEVEL (REFLECTED CELILING PLAN)<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

PERIMETER PV PLAN DETAIL AT PV LEVEL<br />

1 50% DD MR WS 06/29/17<br />

0 03 CANOPY TENDER ISSUE MR WS 06/12/17<br />

Rev Description Apvr Chk'd Date<br />

Client<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

EXPO 2020 Lehbab Road,<br />

DWC South<br />

Dubai - United Arab Emirates<br />

T: +971 4 555 2020<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

GLS-120<br />

TEMPERED GLASS, DOUBLE LAYERED,<br />

FRIT PATTERN<br />

MTL-411<br />

ALUMINUM PV FRAMING<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

4<br />

600508<br />

GLS-120<br />

TEMPERED GLASS, DOUBLE LAYERED,<br />

FRIT PATTERN<br />

MTL-411<br />

ALUMINUM PV FRAMING<br />

MTL-321<br />

METAL WALL PANEL<br />

MTL-320<br />

METAL FLOOR PANEL<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

Development Manager<br />

Project Manager<br />

Local Consultant<br />

Emaar Properties PJSC<br />

P.O. Box 9440, Dubai, UAE<br />

T: +971 4 3673333<br />

F: +971 4 3673000<br />

enquiry@emaar.ae<br />

Turner International Middle East, Ltd.<br />

Turner Construction - International LLC<br />

P.O. Box 13036 - Dubai, UAE<br />

P: +971 4 337 0990<br />

F: +971 4 334 8216<br />

tci.dxb@tcco.com<br />

Floor 2, Hassanicor Building, Al Barsha First<br />

P.O. Box 454801, Dubai, UAE<br />

T: +971 4 399 4788<br />

F: +971 4 399 4780<br />

rpedubai@emirates.net.ae<br />

VAR<br />

2,500<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

Design Architect<br />

637 West 27th Street<br />

New York, New York 10001<br />

T: +01 212.693.3600<br />

Parcel IDE / Community<br />

5219784 / Madinat Al Mataar<br />

Project Title<br />

EXPO2020 SUSTAINABILITY PAVILION<br />

Project Adress<br />

Drawing Title<br />

CANOPY LOUVER EXPLODED AXON DETAIL<br />

MTL-320<br />

METAL FLOOR PANEL<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-321<br />

METAL WALL PANEL<br />

MTL-317<br />

STAINLESS STEEL WIRE MESH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-322<br />

METAL CATWALK SUPPORT FRAME<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-211<br />

AESS CATEGORY 4, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

TYPICAL CANOPY LOUVER SECTION DETAIL<br />

EVENT<br />

C144200<br />

00<br />

6<br />

CANOPY ROOF DETAILS<br />

Approved<br />

Seal Date<br />

06/12/17<br />

Designed Drawn Checked<br />

GA KD WS<br />

Model File Ref:<br />

Scale A1 (594x841) Revision No<br />

92001-MDL-C144200-AR-000002 As indicated 1<br />

Drawing No<br />

92001-DWG-C144200-AR-600504<br />

92001-MDL-C144200-AR-000002