캐노피의 특성상 풍하중과 활화중에 의한 변위가 발생하게 되므로, 모든 연결부위는 3방향의 movement를 고려하여 설계 되었습니다. 또한 패널과 패널사이의<br />

팽창과 수축을 고려하여 패널과 패널사이에는 infill 패널을 부착하여 온도변화와 움직임에 따른 roofing system의 fail에 대비하였습니다.<br />

DM Stamp<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

MTL-411<br />

ALUMINUM PV FRAMING<br />

CONTINUOUS CURVED RAIL FOR<br />

MECHANICAL CLEANING SYSTEM<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

MTL-322<br />

METAL CATWALK SUPPORT FRAME<br />

MTL-320<br />

METAL FLOOR PANEL<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

FLUSH MOUNTED LIGHTNING STRIKE PAD<br />

REFER TO MEP DRAWINGS<br />

TELESCOPIC MAINTENANCE LIGHTING<br />

HINGED COVER PLATE<br />

REFER TO MEP DRAWINGS<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

MTL-411<br />

ALUMINUM PV FRAMING<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

MTL-321<br />

METAL WALL PANEL<br />

PLA-202<br />

CURVED NON-SLIP<br />

WALKING SURFACE<br />

MTL-320<br />

METAL FLOOR PANEL<br />

LIGHTNING STRIKE PLATE<br />

REFER TO MEP DRAWINGS<br />

TELESCOPIC MAINTENANCE<br />

LIGHTING MOUNTED TO<br />

OUTSIDE FACE OF CATWALK<br />

EXTENDS UPWARDS THROUGH<br />

ACCESS PANEL<br />

Copyright by Bureau Expo Dubai 2020 (EX20). All rights reserved. This<br />

document may not, in whole or in part, be reproduced, stored, transmitted or<br />

distributed in any form or by any means, whether electronic, mechanical, by<br />

photocopy, recording or otherwise, without the prior written permission of<br />

EX20. Except where otherwise expressly agreed in writing by EX20, EX20<br />

shall have no responsibility or liability for any loss (direct, consequential or<br />

otherwise) which may arise from reliance on or use of this document or the<br />

information contained therein.<br />

DO NOT SCALE THIS DRAWING.<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

4<br />

600508<br />

3<br />

600508<br />

4<br />

600508<br />

3<br />

600505<br />

1,050<br />

7<br />

600508<br />

N<br />

MTL-321<br />

METAL WALL PANEL<br />

MTL-320<br />

METAL FLOOR PANEL<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

6<br />

600508<br />

MTL-412<br />

ALUMINUM PV INFILL PANELS<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

No<br />

Description<br />

<strong>SA</strong>FETY, HEALTH AND ENVIRONMENT INFORMATION<br />

Brief details on the identified hazard symbol referencing the unusual residual<br />

hazards / risks are listed above.<br />

MTL-211<br />

AESS CATEGORY 4, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-211<br />

AESS CATEGORY 4, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-211<br />

AESS CATEGORY 4, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-317<br />

STAINLESS STEEL WIRE MESH<br />

TYP PV AXON DETAIL<br />

TYP PV PLAN DETAIL<br />

TYP PV SECTION DETAIL<br />

1 50% DD MR WS 06/29/17<br />

0 03 CANOPY TENDER ISSUE MR WS 06/12/17<br />

Rev Description Apvr Chk'd Date<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

MTL-411<br />

ALUMINUM PV FRAMING<br />

MTL-321<br />

METAL WALL PANEL<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

MTL-320<br />

METAL FLOOR PANEL<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

MTL-321<br />

METAL WALL PANEL<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

MTL-411<br />

ALUMINUM PV FRAMING<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

4<br />

600508<br />

Client<br />

Development Manager<br />

Project Manager<br />

EXPO 2020 Lehbab Road,<br />

DWC South<br />

Dubai - United Arab Emirates<br />

T: +971 4 555 2020<br />

Emaar Properties PJSC<br />

P.O. Box 9440, Dubai, UAE<br />

T: +971 4 3673333<br />

F: +971 4 3673000<br />

enquiry@emaar.ae<br />

Turner International Middle East, Ltd.<br />

Turner Construction - International LLC<br />

P.O. Box 13036 - Dubai, UAE<br />

P: +971 4 337 0990<br />

F: +971 4 334 8216<br />

tci.dxb@tcco.com<br />

Local Consultant<br />

Floor 2, Hassanicor Building, Al Barsha First<br />

P.O. Box 454801, Dubai, UAE<br />

T: +971 4 399 4788<br />

F: +971 4 399 4780<br />

rpedubai@emirates.net.ae<br />

4<br />

3<br />

Design Architect<br />

600508<br />

600508<br />

637 West 27th Street<br />

New York, New York 10001<br />

T: +01 212.693.3600<br />

6<br />

600505<br />

1,050<br />

1,560<br />

3,540<br />

Parcel IDE / Community<br />

5219784 / Madinat Al Mataar<br />

MTL-320<br />

METAL FLOOR PANEL<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-317<br />

STAINLESS STEEL WIRE MESH<br />

MTL-315<br />

STAINLESS STEEL TENSION RODS<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

LINEAR CATWALK BELOW<br />

MTL-412<br />

ALUMINUM PV INFILL PANELS<br />

PV-1 STANDARD PHOTOVOLTAIC PANEL<br />

PLA-202<br />

CURVED NON-SLIP WALKING SURFACE<br />

MTL-320<br />

METAL FLOOR PANEL<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-212<br />

AESS CATEGORY 1, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

MTL-211<br />

AESS CATEGORY 4, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

Project Title<br />

EXPO2020 SUSTAINABILITY PAVILION<br />

Project Adress<br />

Drawing Title<br />

EVENT<br />

C144200<br />

00<br />

6<br />

CANOPY ROOF DETAILS<br />

MTL-211<br />

AESS CATEGORY 4, APPLIED HIGH<br />

PERFORMANCE FINISH<br />

PV-2 GLASS LAMINATED<br />

PHOTOVOLTAIC PANEL<br />

Approved<br />

Seal Date<br />

06/12/17<br />

OPERABLE PV AXON DETAIL<br />

OPERABLE PV PLAN DETAIL<br />

OPERABLE PV LONGITUDINAL SECTION DETAIL<br />

Designed Drawn Checked<br />

GA KD WS<br />

Model File Ref:<br />

Scale A1 (594x841) Revision No<br />

92001-MDL-C144200-AR-000002<br />

1 : 50 1<br />

Drawing No<br />

92001-DWG-C144200-AR-600505<br />

92001-MDL-C144200-AR-000002

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!