You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
CS-Glow-2Kit CS-Glow-5Kit<br />
CS-Glow-3Kit CS-Glow-6Kit<br />
CS-Glow-4Kit CS-Glow-7Kit<br />
CS-Glow-UV 365 UV LED<br />
CS-Glow-White 400-700nm White LED<br />
CS-Glow-415 415nm Purple LED<br />
CS-Glow-460 460nm Blue LED<br />
CS-Glow-05 505nm Cyan LED<br />
CS-Glow-530 530nm Green LED<br />
CS-Glow-590 590nm Orange LED
CS-ILLUMALIGHT-2<br />
CS-ILLUMACAM-2
CrimeScope® from Spex <strong>Forensic</strong>s<br />
The CrimeScope isThe Ul mate <strong>Forensic</strong> <strong>Light</strong> Source and “The flagship<br />
of the SPEX <strong>Forensic</strong>s product line.” It covers the spectrum<br />
from UV through the visible range and into infrared, in your choice<br />
of systems: 12 wavelengths from UV through the visible spectrum,<br />
15 wavelengths from UV through the visible spectrum, or add the<br />
op onal Infrared kit with four wavelengths in the infrared spectrum<br />
to either one.<br />
Ideally suited as a lab or crime scene instrument, it features a remote<br />
control integrated into the end of the light guide for easy use.<br />
It uses a powerful 500 wa Xenon Arc Lamp, with adjustable filters<br />
providing an almost con nuous output wavelength spectrum in the en re visible range.<br />
The CrimeScope is manufactured under ISO9001 standards and comes complete with goggles, camera filters, heavy duty flexible<br />
arm to hold the light guide in place, carrying case and training.<br />
Mini-CrimeScope® Advance from Spex <strong>Forensic</strong>s<br />
Using new bulb technology, as well as new high<br />
throughput, high durability<br />
interference filters, it produces more light than<br />
the current Mini-CrimeScope®. Intensity and<br />
power allow for be er sensi vity−helping to find<br />
the faintest of evidence in a more compact and<br />
lighter design.<br />
Features a patented filter wheel at the working<br />
end of the liquid light guide. To switch a filter the user need only “flick a thumb” on the hand that is direc ng the light guide. No<br />
other light source manufacturer can make this claim.<br />
Suitable for lab or field use, it has 15 output wavelengths from UV to 600nm, is manufactured under ISO9001 standards, and<br />
comes with goggles, carrying case and training.
NEW SceneScope RUVIS UHD System from Spex <strong>Forensic</strong>s<br />
The SceneScope RUVIS UHD is a 16MP Ultra High Defini on camera<br />
with 4960 x 3324 pixel resolu on, and a full frame chip. It<br />
includes capture so ware with 3 user selectable modes: Fast<br />
Viewing for placement, Focus on the evidence, and High Detail<br />
for Capture at High Resolu on and High Dynamic Range.<br />
Use &<br />
Benefits<br />
The SceneScope RUVIS UHD is a 16MP Ultra High Defini on camera with<br />
4960 x 3324 pixel resolu on, and a full frame chip. It includes capture so -<br />
ware with 3 user selectable modes: Fast Viewing for placement, Focus on<br />
the evidence, and High Detail for Capture at High Resolu on and High Dynamic<br />
Range.<br />
SceneScope RUVIS UHD devices use 254nm UV light but unlike <strong>Forensic</strong> <strong>Light</strong> <strong>Sources</strong> they are not detec ng fluorescence. Instead<br />
the device looks for the reflec ons and sca er of the 254nm light off of the fingerprint ridges. The System can detect fingerprints<br />
on most non-porous surfaces prior to any treatment or a er a cyanoacrylate (Superglue) fuming. Fuming is required when preliminary<br />
examina on yields no results. The two primary RUVIS applica ons are untreated prints on most non-porous surfaces, and<br />
cyanoacrylate (CA) fumed prints.<br />
Smooth, Non-Porous Surfaces<br />
The SceneScope RUVIS UHD Camera allows the<br />
detec on of latent prints, prior to treatment.<br />
This is possible on surfaces that reflect light<br />
very well and do not absorb prints. That is to<br />
say, surfaces that are smooth and non-porous.<br />
Untreated prints with residual moisture show<br />
as white reflec ve ridges on a black background.<br />
Untreated oily prints appear as strong,<br />
black ridges on a shiny background. As<br />
Le : Latent (Untreated) print on soda can, illuminated with 254nm,<br />
visualized at 254nm. Right: Same Image on Le "Zoomed In".<br />
surfaces become more rough or more porous<br />
“superglueing” the print may extend the range<br />
of surfaces on which RUVIS will work.<br />
Detects Latent Prints<br />
The two primary RUVIS applica ons are the detec on and capture of untreated prints on most non-porous surfaces, and cyanoacrylate(CA)<br />
fumed prints. Print collec on can be performed on surfaces such as plas c bags, s cky sides of tape, glossy magazines,<br />
photographs, linoleum le, compact disks, credit cards, etc. – Cyanoacrylate treatment (fuming) will further enhance the<br />
detec on by RUVIS.
Capture an Image Once in High Resolu on<br />
The system is capable of capturing an immense amount of detail in a single image, even if that image covers a large area like an<br />
en re palm. The 16MP Ultra High Defini on Camera is capable of capturing high resolu on images at 254nm that can be enlarged<br />
to visualize all levels of detail. The camera can capture a full palm image that contains all the informa on necessary to "zoom in"<br />
and see individual minu a points.<br />
Le : Fumed palm print on magazine, illuminated with 254nm, visualized at 254nm. Right: Same Image on Le "Zoomed In".<br />
Background Rejec on<br />
Because the SceneScope RUVIS UHD sees the surface detail, it only sees material deposited on those surfaces, not materials "IN"<br />
the surfaces. This allows superior Background Rejec on as the device does not see inks and pa erns in printed material. As long as<br />
the surface does not show rises or indents, the background will disappear.<br />
Le : Ardrox print illuminated and captured in Visible light by a generic digital camera (what the human eye would see)<br />
Right: Same Sample illuminated and captured at 365nm. Effec ve Background Rejec on.<br />
Features & Specs<br />
Camera Specifica ons<br />
Resolu on: 16 million pixels<br />
Frame Rate: 3 User Selectable Opera ng Modes<br />
Search: 10 fps<br />
Fine Focus: 11 fps<br />
Capture: 1.7 fps<br />
Spectral Sensi vity: 250nm to 1100nm<br />
Integra on me: 1ms to 16 seconds<br />
Aspect Ra o: 3:2<br />
Data Transfer: Gigabit Ethernet
SceneScope Advance RUVIS UV Imager from Spex <strong>Forensic</strong>s<br />
The SceneScope Advance imager uses intensified UV reflectance instead of<br />
fluorescence as in <strong>Forensic</strong> <strong>Light</strong> <strong>Sources</strong>. The System can detect fingerprints on most<br />
non-porous surfaces prior to any treatment or a er a cyanoacrylate (Superglue) fuming.<br />
Fuming is required when preliminary examina on yields no results.<br />
NYLON FRAMED<br />
FORENSIC GOGGLES<br />
Tired of having your current<br />
goggles snap, crack<br />
and break? Want<br />
greater comfort? These<br />
nylon framed wrap around goggles are much more<br />
durable, and comfortable. These goggles will fit over<br />
prescrip on glasses, and have adjustable arms.<br />
Each pair comes in their own carrying case.<br />
NL-ARG38
Colored <strong>Forensic</strong> Goggles<br />
These wrap around goggles made of polycarbonate provide personal protec on and ideal wavelength absorp on for use<br />
with forensic alternate light sources. Easily fit over prescrip on glasses. Come in a vinyl<br />
carrying case.<br />
Orange wrap-around goggles provide high<br />
contrast 100% UV protec on, 100% blue<br />
light protec on.<br />
NL-U6032<br />
Yellow wrap-around goggles heightens contrast with 100% UV<br />
protec on.<br />
NL-U50<br />
Red wrap-around goggles provide 100% UV<br />
protec on.<br />
NL-U90<br />
Clear wrap-around goggles provide total UV<br />
protec on with no reduc on in visibility<br />
LASER PROTECTIVE GOGGLES<br />
These goggles provide greater protec on against back-sca ered and reflec ve laser<br />
light. They provide 180-532nm OD 7+<br />
protec on.<br />
These goggles are commonly used with the Coherent TracER systems<br />
NL-ARG60<br />
Laser Fit– Over Goggles<br />
Camera Filters &<br />
Stepping Rings<br />
These high quality filters allow you to photograph what your eyes can see when using forensic alternate<br />
light sources<br />
and the appropriate forensic goggles. It is important that these high pass filters approximate the<br />
characteris cs<br />
of the goggles you wear, in order to capture as<br />
close as possible the trace evidence and detail<br />
that the inves gator sees.<br />
HE-095NAD086 UV Haze 60 mm filter<br />
HE-095NAD091 Yellow 62 mm filter<br />
HE-095NAD090 Red 62 mm filter<br />
HE-095BOO018 Infra Red High Pass filter (> 720 nm)<br />
HE-6267 Camera stepping ring 62/67, 62/67<br />
HE-5258 Camera stepping ring 52/58, 52/58<br />
HE-4958 Camera stepping ring49/58, 49/58<br />
HE-095KDN025 22 Orange 62 mm filter