Troubleshooting<br />

Troubleshooting<br />

The areas <strong>and</strong> steps for inspection are determined according to various malfunctions. Use the chart below to<br />

verify the malfunction symptoms in order to diagnose the related area.<br />

I. Insufficient <strong>air</strong>flow <strong>and</strong>/or no <strong>air</strong>flow from <strong>air</strong> ports<br />

1 Insufficient <strong>air</strong>flow <strong>and</strong>/or no <strong>air</strong>flow from <strong>air</strong> ports.<br />

Malfunction<br />

description<br />

Possible causes<br />

1. malfunction in <strong>air</strong> port or passage<br />

1. malfunction in vent mode <strong>system</strong>: steps 1-4<br />

2. malfunction in heat mode <strong>system</strong>: step 5<br />

3. malfunction in defroster mode <strong>system</strong>: steps 6-8<br />

Troubleshooting procedure<br />

Step Inspection Action<br />

1 Inspect <strong>air</strong>flow mode control <strong>system</strong> of front<br />

climate control unit.<br />

• When <strong>air</strong>flow mode control knob is operated,<br />

check whether appropriate resistance can be felt<br />

<strong>and</strong> the knob can be moved to its full range freely.<br />

Yes<br />

No<br />

Go to next step.<br />

Go to step 1 of troubleshooting<br />

index no. 3.<br />

2 Verify whether malfunction is in vent mode or<br />

other modes.<br />

• Does <strong>air</strong> blow out in vent mode?<br />

Yes Go to step 5.<br />

No<br />

Go to next step.<br />

3 Inspect <strong>air</strong> port.<br />

• Is <strong>air</strong> port clogged?<br />

4 Verify that duct in dashboard is installed.<br />

• Is duct in dashboard properly installed?<br />

5 Verify whether malfunction is in heat mode or<br />

defroster mode.<br />

• Does <strong>air</strong> blow out in heat mode?<br />

Yes<br />

No<br />

Yes<br />

No<br />

Yes<br />

No<br />

Remove obstruction, <strong>and</strong> then go to<br />

step 9.<br />

Go to next step.<br />

Inspect <strong>air</strong> passage for clogging,<br />

deformity <strong>and</strong> <strong>air</strong> leakage, then go<br />

to step 9.<br />

Install duct securely in the proper<br />

position, then go to step 9.<br />

Go to next step.<br />

Check <strong>air</strong> port for clogging, then go<br />

to step 9.<br />

6 Inspect defroster mode.<br />

• Dose <strong>air</strong> blow out in defroster mode?<br />

Yes Operation is normal. Recheck<br />

malfunction symptoms.<br />

No<br />

Go to next step.<br />

U-14