Voltage Sensitive Relays<br />
High cur rent remote oper ated ( VSR)<br />
Range HigHligHts<br />
Dual battery sensing<br />
<strong>Remote</strong> emergency parallel function:<br />
the 701-MDVS and 720-MDVS can be<br />
operated through a momentary button<br />
on the dash which will parallel the<br />
batteries for a preset time of 10 minutes.<br />
Once this 10 minutes has passed, if the<br />
voltage is up high enough for the voltage<br />
sensitive switch to operate, it will stay<br />
engaged. If not, it will disengage.<br />
Engine run sensing: VSR will engage<br />
when the voltage on either start or<br />
house battery reaches 13.7 volts. If the<br />
combined battery voltage drops below<br />
13.0 volts and the engine is not running,<br />
after 5 seconds the contacts will open<br />
and stay open until the start or house<br />
battery voltage exceeds 13.7 volts. If the<br />
combined battery voltage drops below<br />
12.2 volts and the engine is running, after<br />
5 minutes the contacts will open and stay<br />
open until the start or house battery<br />
voltage exceeds 13.7 volts. If voltage<br />
drops below 13 volts and stays above12.2<br />
volts on either start or house battery<br />
while engine is running, the VSR will stay<br />
engaged.<br />
Manual override option<br />
The advantages of using a high current<br />
VSR is that it will cover your dual battery<br />
charging requirements and emergency<br />
parallel operation in one unit.<br />
High Current <strong>Remote</strong> operated VSR<br />
Part No. mm<br />
in<br />
L x W x H L x W x H<br />
701-MDVS 68 x 68 x 101 2.7 x 2.7 x 4<br />
720-MDVS 102 x 102 x 110 4 x 4 x 4.3<br />
701-MDVS-24V 68 x 68 x 101 2.7 x 2.7 x 4<br />
720-MDVS-24V 102 x 102 x 110 4 x 4 x 4.3<br />
80-701-0018-00 68 x 68 x 101 2.7 x 2.7 x 4<br />
80-720-0018-00 102 x 102 x 110 4 x 4 x 4.3<br />
High Current <strong>Remote</strong> operated VSR<br />
Part No. Volts Rating Engages Disengages<br />
(V) (A) (V DC) (V DC)<br />
701-MDVS 12 275 13.7 12.2 - 13.00<br />
720-MDVS 12 500 13.7 12.2 - 13.00<br />
701-MDVS-24V 24 275 27.4 24.4 - 26.00<br />
720-MDVS-24V 24 500 27.4 24.4 - 26.00<br />
80-701-0018-00 12/24 275 Emergency Parallel Only<br />
80-720-0018-00 12/24 500 Emergency Parallel Only<br />
701-MDVS<br />
Also available in<br />
Emergency parallel only<br />
(no voltage sensitive<br />
function). See table.<br />
OUTPUT<br />
INPUT<br />
48 LEADING ELECTRICAL DESIGN<br />
80-724-0007-00<br />
RED<br />
GREEN<br />
BLACK<br />
IT IS IMPERATIVE THAT THE NEGATIVE (BLACK) FOR THE MD/MDVS IS TAKEN<br />
FROM THE SAME BATTERY THAT IT IS ISOLATING. FAILURE TO<br />
DO THIS WILL CAUSE THE UNIT TO WORK ERRATICALLY. ONLY ONE NEGATIVE<br />
MUST BE SUPPLIED TO EACH UNIT FOR CORRECT OPERATION.<br />
Dual operation VSR<br />
and Emergency Parallel<br />
The High Current <strong>Remote</strong><br />
Operated VSR (Voltage Sensitive<br />
Relay), uses the same operation<br />
as the motor driven Battery<br />
Switches.<br />
For the remote operation of the 701-MDVS and 720-MDVS voltage<br />
sensitive battery switches. It can be mounted standalone or within the<br />
Contour Connect panel range.<br />
80-724-0006-00<br />
701<br />
701<br />
(ON)/OFF<br />
SWITCH<br />
THESE TWO CABLES MUST BE<br />
TERMINATED INTO WAGO PLUG<br />
720-MDVS