Prospector Series <strong>Poppet</strong> <strong>Valves</strong><br />

4-Port/2-Position (4 way) Inline & Subbase<br />

Below listed operators have non-locking override and 110/120V 50/60Hz coil.<br />

Symbol Solenoid Basic Port Model Operating Pilot Weight Repair Kit§<br />

Pilot Size Size Pressure Pressure lbs. (kg)<br />

psig (bar) psig (bar)<br />

CYL2 CYL1<br />

IN EXH<br />

Internal Pilot<br />

1/4"<br />

1/4"<br />

3/8"<br />

F1012C-00-CY<br />

F1013C-00-CY<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

1.91<br />

(0.87)<br />

1.91<br />

(0.87)<br />

53477-06<br />

53473-05<br />

3/8" F1023C-00-CY<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

2.50<br />

(1.13)<br />

53474-06<br />

1/2" 1/2" F1024C-00-CY<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

2.50<br />

(1.13)<br />

53474-06<br />

3/4" F1025C-00-CY<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

2.50<br />

(1.13)<br />

53474-06<br />

3/4" F1035C-00-CC<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

2.50<br />

(1.13)<br />

53475-06<br />

1" 1" F1036C-00-CC<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

4.49<br />

(2.04)<br />

53475-06<br />

1-1/4" F1037C-00-CC<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

4.49<br />

(2.04)<br />

53475-01<br />

External Pilot<br />

1/4"<br />

1/4"<br />

3/8"<br />

F1012H-00-CY<br />

F1013H-00-CY<br />

0 - 150<br />

(0 - 10.3)<br />

0 - 150<br />

(0 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

1.91<br />

(0.87)<br />

1.91<br />

(0.87)<br />

53477-06<br />

53473-05<br />

CYL2 CYL1<br />

IN EXH<br />

3/8" F1023H-00-CY<br />

0 - 150<br />

(0 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

2.50<br />

(1.13)<br />

53474-06<br />

1/2" 1/2" F1024H-00-CY<br />

0 - 150<br />

(0 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

2.50<br />

(1.13)<br />

53474-06<br />

3/4" F1025H-00-CY<br />

0 - 150<br />

(0 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

2.50<br />

(1.13)<br />

53474-06<br />

3/4" F1035H-00-CC<br />

0 - 150<br />

(0 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

2.50<br />

(1.13)<br />

53475-06<br />

1" 1" F1036H-00-CC<br />

0 - 150<br />

(0 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

4.49<br />

(2.04)<br />

53475-06<br />

1-1/4" F1037H-00-CC<br />

30 - 150<br />

(0 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

4.49<br />

(2.04)<br />

53475-01<br />

CYL2 CYL1<br />

Subbase<br />

Internal Pilot<br />

1/2"<br />

1"<br />

1/2"<br />

1"<br />

F2214C-00-CY<br />

F2226C-00-CC<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3)<br />

4.67<br />

(2.12)<br />

9.33<br />

(4.24)<br />

53474-06<br />

53475-06<br />

IN EXH<br />

Subbase<br />

External Pilot<br />

1/2"<br />

1"<br />

1/2"<br />

1"<br />

F2214H-00-CY<br />

F2226H-00-CC<br />

0 - 150<br />

(0 - 10.3)<br />

0 - 150<br />

(0 - 10.3)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

30 - 150<br />

(2.1 - 10.3†)<br />

4.67<br />

(2.12)<br />

9.33<br />

(4.24)<br />

53474-06<br />

53475-06<br />

† External Pilot Supply: Pilot supply pressure must be equal to or greater than the operating pressure.<br />

§ Repair Kit: Kits contain all elastomers necessary to service one valve body.<br />

Technical Details for Prospector Solenoid Pilot Operated <strong>Valves</strong><br />

Rating 90 - 105% Continuous Duty; and 85 - 105% for CC.<br />

Power Requirements CC: 8 WDC, 8 WAC. CY: 6 WDC, 7 WAC. (See Options on VAL-12-13).<br />

Electrical Connection CC: Form A per DIN 43650; CE, CF, CY: Industry Standard Form B per DIN 43650.<br />

Manual Override Non-Locking (See Options on VAL-12-13)<br />

Protection Class IP65 (NEMA 4) (See Options on VAL-12-13)<br />

Coil Type Class H. Molded with 3-pin plug in connector. (See Options on VAL-12-13).<br />

Plug Cable grips for cables 6 to 8 mm (1/4" to 5/16") in diameter.<br />

VAL-12-12 Littleton, CO USA Phone: 303-794-2611 www.norgren.com