19.10.2018 Views

Erler-Zimmer 2018-2019

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2<br />

1<br />

1 12-Lead Arrhythmia Simulator<br />

Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free<br />

defibrillation cable.<br />

• Connects directly to monitor; does not work with manikin<br />

• Simulate electrical capture with your external pacer. Press simulator capture key to select one<br />

of four preset pacing capture levels: 70, 80, 90, or 100mA. When pacer current is greater than<br />

selected capture level, paced beats appear on your monitor. Waveforms for pacing include: Sinus<br />

Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd<br />

degree type II A-V block with PVCs, and 3rd degree A-V block.<br />

• Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator. Activate<br />

“convert” feature to select - before defib discharge - another rhythm to run immediately after<br />

defib discharge. Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach<br />

(low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs,<br />

Asystole, and NSR.<br />

• Generate realistic 12-lead ECG rhythms. Connect your ECG cable to simulator’s 10 ECG snaps.<br />

Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.<br />

Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal<br />

ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.<br />

• LED indicators: pacer pulse detection, defib discharge detection, and low battery.<br />

Zoll<br />

• Ref.no. R13001-1<br />

Physio Medtronic and Marquette Quick Combo<br />

• Ref.no. R13001-2<br />

Heart Start/Philips with late VF Waveform<br />

• Ref.no. R13001-3<br />

Philips<br />

• Ref.no. R13001-4<br />

MRL, Welch Allyn R2<br />

• Ref.no. R13001-5<br />

2 12-Lead Arrhythmia Simulator with Manikin Overlay<br />

Use on any large-sized manikin or simulator to change it into a 12-lead trainer. Pace and defibrillate<br />

directly on the overlay system connected to the interactive 12-lead ECG simulator, included with the<br />

overlay. You may purchase optional defibrillation training cables that allow you to have hand-free<br />

defibrillation simulation, with up to 360 joules, as well as electrical capture with your external pacer.<br />

The simulator capture key is used to select one of four preset pacing capture levels: 70, 80, 90 or<br />

100mA. When the pacer current is greater than the selected capture level, paced beats will appear on<br />

your monitor. Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type<br />

I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V<br />

block. Simulate cardioversion with your manual, semiautomatic, or automatic defibrillator. Waveforms<br />

for defibrillator training include: V. Fib, V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A.<br />

Flutter, zPSVT, Sinus Tach, Sinus rhythm, Sinus rhythm with PVCs, and Asystole. Generate ST segment<br />

and T wave of abnormalities, including: Anterior MI, Inferior MI, Antero-Septal ST elevation, Anterior<br />

ST depression, Lateral ST elevation, and Inferior ST elevation. LEDs indicate: pacer pulse detection,<br />

defib discharge detection, and low battery.<br />

Medium size skin, Zoll<br />

• Ref.no. R13002-1<br />

Large size skin, Zoll<br />

• Ref.no. R13002-2<br />

Medium size skin, Physio<br />

• Ref.no. R13002-3<br />

Large size skin, Physio<br />

• Ref.no. R13002-4<br />

Medium size skin, Marquette<br />

• Ref.no. R13002-5<br />

Large size skin, Marquette<br />

• Ref.no. R13002-6<br />

Medium size skin, Heartstream<br />

• Ref.no. R13002-7<br />

Large size skin, Heartstream<br />

• Ref.no. R13002-8<br />

Medium size skin, Heartstart<br />

• Ref.no. R13002-9<br />

Large size skin, Heartstart<br />

• Ref.no. R13002-10<br />

Medium size skin, R2<br />

• Ref.no. R13002-11<br />

Large size skin, R2<br />

• Ref.no. R13002-12<br />