25.02.2019 Views

FIS-483 Consolidated Engineering Study Report

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Marathon Petroleum Company, Catlettsburg Refinery, KY<br />

Capacity Improvement <strong>Study</strong> of LPCCR Platformer Heater (1-44-B-1/2/3/4)<br />

This revamped design of the heater with new convection section will increase the<br />

charge rate capacity of the heater to 24.5 MBPD. We have sized the heater for<br />

the permitted firing rate of 280 MMBtu/hr (LHV). The total absorbed heat duty is<br />

246.5 MMBtu/hr. The total process duty is 191.7 MMBtu/hr. Debutanizer heat<br />

duty is 5.12 MMBtu/hr and Waste heat duty is 49.63 MMBtu/hr.<br />

The table below shows the comparison of existing design, maximum charge case<br />

and proposed design heat duties and the percentage flow through split flow coils:<br />

Heater<br />

Section<br />

No. 1<br />

Interheater<br />

Charge<br />

Heater<br />

No. 2 Inter<br />

Heater<br />

No. 3 Inter<br />

Heater<br />

Existing<br />

Design<br />

Case<br />

Maximum<br />

Charge case<br />

Proposed<br />

Design<br />

Case<br />

Extra Heat<br />

Duty<br />

Flow<br />

through<br />

split flow<br />

coils<br />

Heat Duty, MMBtu/hr %<br />

37.46 42.97 66.13 23.16 26.46<br />

26.12 36.20 50.08 13.88 22.41<br />

28.70 35.56 49.20 13.64 22.93<br />

13.98 19.99 26.32 6.33 24.70<br />

Total Duty 106.3 134.7 191.7 57.0<br />

The process heat duty is being increased by almost 85.4 MMBtu/hr from the<br />

existing design heat duty and about 57 MMBtu/hr from the current operating levels<br />

of 134.7 MMBtu/hr.<br />

1.5 Cost Estimation<br />

<strong>FIS</strong> has developed ±30% cost estimates for Platformer Heater(1-44-B-1/2/3/4)<br />

revamp. The estimated cost for the proposed recommendation is $ 9.99 Million.<br />

The cost includes design engineering supply and erection of the new convection<br />

section. It also includes split flow piping and instrumentation.<br />

We hope you find our report helpful and informative. We will provide you all the help<br />

you need in implementing these changes. We will be happy to provide you with<br />

follow up support, should you need further information or clarifications.<br />

Furnace Improvements<br />

Low Cost Solutions for Fired Heaters 12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!