Marathon Petroleum Company, Catlettsburg Refinery, KY<br />

Capacity Improvement <strong>Study</strong> of LPCCR Platformer Heater (1-44-B-1/2/3/4)<br />

Figure 5: Recycle Gas Flow Rate, Mlb/hr<br />

FLOWRATE, MLB/HR<br />

24<br />

22<br />

20<br />

18<br />

16<br />

AVERAGE=19.1 MLB/HR<br />

DESIGN=15.7 MLB/HR<br />

(CALCULATED)<br />

14<br />

2-Nov-17 13-Jan-18 27-Mar-18 8-Jun-18<br />

TIME<br />

20-Aug-18 1-Nov-18<br />

Note: Recycle Gas molecular weight of 5.41 lb/lbmol (provided for only one day in<br />

operating data) was considered in this calculation.<br />

Figure 6: Recycle Gas / Naphtha Flow Rate Ratio<br />

0.10<br />

AVERAGE=0.08 LB/LB<br />

(CALCULATED)<br />

FLOW RATE RATIO, LB/LB<br />

0.09<br />

0.08<br />

0.07<br />

0.06<br />

0.05<br />

2-Nov-17 13-Jan-18 27-Mar-18 8-Jun-18<br />

TIME<br />

20-Aug-18 1-Nov-18<br />

Furnace Improvements<br />

Low Cost Solutions for Fired Heaters 40