Marathon Petroleum Company, Catlettsburg Refinery, KY<br />

Capacity Improvement <strong>Study</strong> of LPCCR Platformer Heater (1-44-B-1/2/3/4)<br />

Detailed Design <strong>Engineering</strong> of proposed modifications<br />

Any Mechanical / Structural / Civil design and calculations<br />

Any Piping, Instrumentation and electrical design and calculations.<br />

Any other activity not specifically mentioned in the scope of service<br />

2.2 Design Basis<br />

The following data from the heater datasheet is used for evaluating the existing<br />

design case of the Platformer heater:<br />

Table 1: Existing Design Rich Case Data<br />

Parameters<br />

Unit<br />

Charge<br />

Heater<br />

Inter<br />

Heater 1<br />

Inter<br />

Heater 2<br />

Inter<br />

Heater 3<br />

Process Heat Duty MMBtu/hr 26.12 37.46 28.7 13.98<br />

Naphtha Charge<br />

Rate (Calculated)<br />

Recycle Gas Flow<br />

Rate (Calculated)<br />

MBPD 18.2<br />

MMSCFD 26.4<br />

Total Feed Flow Rate lb/hr 211,731<br />

Inlet Temperature °F 866 801 852 934<br />

Outlet Temperature °F 1,010 1,010 1,010 1,010<br />

Temperature Rise °F 144 209 158 76<br />

Inlet Pressure psig 77 71.8 68.2 63.0<br />

Outlet Pressure psig 75.8 69.8 66.2 61.3<br />

Coil Pressure Drop psi 1.2 2.0 2.0 1.7<br />

Waste Heat Duty MMBtu/hr 50.5<br />

Firing Rate MMBtu/hr 177.51<br />

Furnace Improvements<br />