FREE, comprehensive 80-page catalog that features a complete line of equipment to protect operators of cutting and turning machines. These products comply with OSHA and ANSI standards. The polycarbonate and steel shields found in this catalog can be applied to drill presses, lathes, milling machines, bench grinders, band saws, and disc and belt sanders. The catalog also offers emergency-stop devices, disconnect switches, magnetic motor starters, lockouts, and danger signs.

FREE, comprehensive 80-page catalog that features a complete line of equipment to protect operators of cutting and turning machines. These products comply with OSHA and ANSI standards. The polycarbonate and steel shields found in this catalog can be applied to drill presses, lathes, milling machines, bench grinders, band saws, and disc and belt sanders. The catalog also offers emergency-stop devices, disconnect switches, magnetic motor starters, lockouts, and danger signs.

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DISCONNECT SWITCHES, MOTOR STARTERS, AND ACCESSORIES<br />

LOCKOUT VALVES<br />

SLIDE-OPERATED VALVE<br />

This three-way valve is operated with the manual movement of a<br />

slide that opens and closes the valve. This valve shuts off air at the<br />

machine and then bleeds off downstream air. It can be locked only<br />

in the off position.<br />

EEZ-ON VALVE<br />

This valve shuts off air supply to the machine and bleeds downstream<br />

air when the valve is closed. When the valve is open, it gradually allows<br />

air into the air system to prevent damage to air components. It can be<br />

locked only in the off position. This valve is furnished with a muffler.<br />

PART NO.<br />

RCD-113 ½"<br />

RCD-114 ¾"<br />

PART NO.<br />

PORT SIZE<br />

IN-OUT<br />

IN-OUT<br />

PORT SIZE<br />

RCD-121 ½" ¾"<br />

RCD-122 ¾" ¾"<br />

EXHAUST<br />

SINGLE-PHASE DISCONNECT SWITCH WITH MAGNETIC MOTOR<br />

STARTER AND SELF-LATCHING EMERGENCY-STOP BUTTON<br />

This single-phase unit is designed <strong>for</strong> motors that have built-in overloads. Typical applications <strong>for</strong><br />

these combinations include smaller crimping machines, grinders, drill presses, and all types of saws.<br />

PART NO. CSS-055 (115 V, ½ HP MAX.)<br />

The 115-V, 15-A disconnect switch and nonreversing magnetic motor starter are housed in a NEMA<br />

12 enclosure. Enclosure size is 8" x 6" x 3½". It includes a self-latching red emergency-stop palm<br />

button and a green motor control on push button. It can be used on machines with 115-V power and<br />

is rated up to ½ HP maximum.<br />

The disconnect switch has a rotary operating handle which is lockable in the off position only. This<br />

meets OSHA regulations and ANSI standards.<br />

For machines with 230-V AC single-phase motors, a trans<strong>for</strong>mer is required to reduce the control<br />

circuit voltage to 115-V AC in order to comply with NFPA 79. See the RSD series disconnect<br />

switches, motor starters, and combinations on pages 64-65.<br />

SINGLE-PHASE STARTER WITH SELF-LATCHING EMERGENCY-<br />

STOP BUTTON<br />

PART NO. CSF-082 (115 V, ½ HP MAX.)<br />

The 115-V, 15-A nonreversing magnetic motor starter, self-latching red emergency-stop palm<br />

button, and green motor control on push button are housed in a NEMA 4 polycarbonate enclosure.<br />

Enclosure size is 5" x 5" x 4". It can be used <strong>for</strong> machines with 115-V power and is rated up to ½<br />

HP maximum.<br />

For machines with 230-V AC single-phase motors, a trans<strong>for</strong>mer is required to reduce the control<br />

circuit voltage to 115-V AC in order to comply with NFPA 79. See the RSD series disconnect<br />

switches, motor starters, and combinations on pages 63-64.<br />

PART NO. CSF-301 (115 V, 2 HP MAX.)<br />

The 115-V, 30-A nonreversing magnetic motor starter, self-latching red emergency-stop palm<br />

button, and green motor control on push button are housed in a NEMA 12 enclosure. Enclosure size<br />

is 8" x 6" x 6". It can be used <strong>for</strong> machines with 115-V power and is rated up to 2 HP maximum.<br />

For machines with 230-V AC single-phase motors, a trans<strong>for</strong>mer is required to reduce the control<br />

circuit voltage to 115-V AC in order to comply with NFPA 79. See the RSD series disconnect<br />

switches, motor starters, and combinations on pages 63-64.<br />