#8841 #8841) Mouse - USB, Business Black with Keyboard Attachment Cable<br />

Provides a three button USB mouse <strong>and</strong> a cable for attachment to a keyboard.<br />

Attributes provided: 3-Button USB Mouse<br />

Attributes required: Keyboard with USB Mouse Attachment Port<br />

For 9117-MMA (#8841) <strong>and</strong> 9119-FHA (#8841)<br />

► Minimum required: 0<br />

► Maximum allowed: no max (Initial order maximum: no max)<br />

► OS level required: None<br />

► Initial Order/MES/Both/Supported: Both<br />

► CSU: Yes<br />

► Return parts MES: No<br />

#8847 #8847 - Base Serv Inface Cable-2 Drw<br />

Connects the components in each processor enclosure or drawer to the active Service Processor for<br />

monitoring system functions. This cable connects to the Service Interface Cards at the rear of each processor<br />

enclosure of a two-drawer or 8-way system.<br />

#8847 <strong>and</strong> #5657 are identical cables, but #8847 is used with an initial order of a 1/8-way CBU Edition or<br />

2/8-way Base Edition.<br />

Attributes provided: Service Interface<br />

Attributes required: System with two CEC enclosures<br />

For 9406-MMA (#8847)<br />

► Minimum required: 0<br />

► Maximum allowed: 1 (Initial order maximum: 1)<br />

► OS level required: Not applicable<br />

► Initial Order/MES/Both/Supported: Both<br />

► CSU: No<br />

#8849 #8849 - Base Serv Inface Cable-4 Drw<br />

Connects the components in each processor enclosure or drawer to the active Service Processor for<br />

monitoring system functions. This cable connects to the Service Interface Cards at the rear of each processor<br />

enclosure of a four-drawer or 16-way system.<br />

Note: This feature is converted to #5560 on unified <strong>POWER6</strong> MTMs.<br />

#8849 <strong>and</strong> #5660 are identical cables, but #8849 is used with an initial order of a 2/16-way CBU Edition or<br />

4/16-way Base Edition.<br />

Attributes provided: Service Interface<br />

Attributes required: System with four CEC enclosures<br />

For 9406-MMA (#8849)<br />

► Minimum required: 0<br />

► Maximum allowed: 1 (Initial order maximum: 1)<br />

► OS level required: <strong>IBM</strong> i 5.4 with V5R4M5 machine code or later<br />

► Initial Order/MES/Both/Supported: Both<br />

► CSU: No<br />

704 <strong>IBM</strong> <strong>Power</strong> <strong>570</strong> <strong>and</strong> <strong>IBM</strong> <strong>Power</strong> <strong>595</strong> (<strong>POWER6</strong>) System Builder