licht.wissen No. 09 “Refurbishment in Trade, Commerce and Administration“
An extensive survey of offices, workshops and school classrooms shows that lots of lighting installations are obsolete. licht.wissen 09 informs that refurbishment sustainably lowers energy consumption, saves costs and makes for a significant improvement in lighting quality. This booklet from licht.de contains impartial advice for consultations with commercial clients. It also flags up web tools for assessing lighting installations and making design recommendations. Free Download at www.licht.de/en
An extensive survey of offices, workshops and school classrooms shows that lots of lighting installations are obsolete. licht.wissen 09 informs that refurbishment sustainably lowers energy consumption, saves costs and
makes for a significant improvement in lighting quality.
This booklet from licht.de contains impartial advice for consultations with commercial clients. It also flags up web tools for assessing lighting installations and making design recommendations. Free Download at www.licht.de/en
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
licht.wissen 09
Refurbishment in Trade, Commerce and Administration
Luminaire replacement
makes for savings
General shop lighting is another area where old
luminaires for fluorescent lamps can often be
replaced one for one by LED luminaires. Energy
savings of more than 50 percent are often achieved
here.
Even more energy can be saved by refurbishing the
supplementary accent lighting. Where luminaires
for low-voltage halogen lamps are installed, for
example, replacing them with LED luminaires – typically
swapping the halogen lamps for 17 Watt LEDs –
can reduce energy requirements by as much as
70 percent.
Take care to ensure that LED luminaires with good
colour rendering and appropriate light distribution
are used.
32
Sample solution
9.20 m
28
13.00 m
Old installation
New installation
Louver luminaires 2 x 36 W, LLB comp.
LED recessed luminaires
and downlights 2 x 18 W*
with microprismatic enclosure
and LED downlights
Number of luminaires 12 + 5 12 + 5
System wattage per luminaire 84 W / 52 W 40 W / 21 W
Effective operating hours / year** 3,600 3,600
Energy / year 4,565 kWh 2,106 kWh
Energy saving 54%
*Typical luminaire light output ratio approx. 70%. 2 x 3,350 lm x 65/100 = 4,355 lm, 2 x 1,200 lm x 70/100 = 1.680 lm
**The effective operating hours take account of need-based dimming as well as the activation/deactivation of lights due to presence and daylight detection and constant lighting control.
Energysaving
54%