CIMclad: <strong>Formalised</strong> <strong>per<strong>for</strong>mance</strong> <strong>specifications</strong> <strong>for</strong> <strong>rainscreen</strong> <strong>cladding</strong><br />

AIR PERMEABILITY THROUGH AIR BARRIER:<br />

The maximum design value <strong>for</strong> air leakage through the air barrier at a<br />

differential pressure of 50 Pascals is ______ m³/hr/m².<br />

(Normally delete this clause – only used <strong>for</strong> pressure equalised<br />

<strong>rainscreen</strong>s)<br />

NBS Section H92 400<br />

Air Permeability<br />

4 Backing Wall<br />

Per<strong>for</strong>mance<br />

THERMAL PROPERTIES:<br />

- Method <strong>for</strong> calculating the thermal transmittance (U-value) of the<br />

<strong>rainscreen</strong> wall: ______<br />

- Average U-value of <strong>rainscreen</strong> wall: ______W/m²K.<br />

430<br />

Thermal<br />

Resistance<br />

FIRE RESISTANCE OF BACKING WALL:<br />

To BS 476- 21 and not less than ______<br />

480<br />

Fire Resistance<br />

INTERNAL SURFACE SPREAD OF FLAME OF BACKING WALL:<br />

To BS 476-7, Class ______<br />

485<br />

CAVITY FIRE BARRIERS:<br />

To BS 476-20 and must resist the passage of flame and smoke <strong>for</strong> not<br />

less than ______<br />

490<br />