CIMclad: <strong>Formalised</strong> <strong>per<strong>for</strong>mance</strong> <strong>specifications</strong> <strong>for</strong> <strong>rainscreen</strong> <strong>cladding</strong><br />

LARGE TEST SPECIMEN: ______<br />

- Drawing references: ______<br />

- Overall dimensions ______ m high x ______ m wide.<br />

- Features: ______<br />

- Test sequence(s): As clause(s) ______<br />

(This clause <strong>for</strong> complete wall system ie – <strong>rainscreen</strong> system + integral<br />

backing wall)<br />

NBS Section H92 540<br />

Large Test<br />

Specimen<br />

11 Testing (Contd)<br />

SMALL TEST SPECIMEN: ______<br />

- Drawing references: ______<br />

- Overall dimensions ______ m high x ______ m wide.<br />

- Features: ______<br />

- Test sequence(s): As clause(s)______<br />

(This clause applicable to <strong>rainscreen</strong> only system ie – no integral<br />

backing wall)<br />

550<br />

Small Test<br />

Specimen<br />

TEST SEQUENCE: To CWCT ‘Standard <strong>for</strong> testing ventilated<br />

<strong>rainscreen</strong>s’, Table 2 as follows:<br />

- Air permeability: As clause ______<br />

- Weathertightness/water penetration: As clause ______<br />

- Windloading: As clause ______<br />

(Use this clause <strong>for</strong> standard tests)<br />

560<br />

Test Sequence<br />

TEST SEQUENCE: To CWCT ‘Standard <strong>for</strong> testing ventilated<br />

<strong>rainscreen</strong>s’ Table 2 and clauses 3.10 and 3.11 as follows:<br />

- Air permeability: As clause ______<br />

- Weathertightness/water penetration: As clause ______<br />

- Windloading: As clause ______<br />

- Building movement/racking procedure: ______<br />

Repeat test(s): ______<br />

- Thermal cycling regime: ______<br />

Repeat test(s): ______<br />

- Sparge bar: ______<br />

- Hosepipe: ______<br />

- Ultimate strength: ______<br />

(Use this clause <strong>for</strong> standard tests plus choice of other tests)<br />

570<br />

AIR PERMEABILITY TESTS:<br />

- To CWCT ‘Standard <strong>for</strong> testing of ventilated <strong>rainscreen</strong>s’, clauses<br />

3.3 and 3.3.1<br />

- Test pressure: As clause 410.<br />

- Allowable leakage rates: As clause 390.<br />

595<br />

Air Permeability<br />

Tests<br />

Standard Tests<br />

July 2001 Page 18 of 18