Formalised performance specifications for rainscreen cladding
Formalised performance specifications for rainscreen cladding
Formalised performance specifications for rainscreen cladding
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CIMclad: <strong>Formalised</strong> <strong>per<strong>for</strong>mance</strong> <strong>specifications</strong> <strong>for</strong> <strong>rainscreen</strong> <strong>cladding</strong><br />
GENERAL SEALANTS:<br />
Must be stable and compatible with all contact products and finishes<br />
and be selected in accordance with BS 6213 from:<br />
Silicone to BS 5889<br />
One part polysulfide to BS 5215<br />
Two part polysulfide to BS 4254<br />
One or two part polyurethane.<br />
NBS Section H92 770<br />
Sealants<br />
20 Rainscreen<br />
Materials and<br />
Finishes related<br />
Standards<br />
THERMAL INSULATION:<br />
- Material: ______<br />
Manufacturer and reference: ______<br />
Thickness: Not less than ______ mm.<br />
- Attached to the outer face or supported within the backing wall so as<br />
not to bulge, sag, delaminate or detach during installation or in situ<br />
during the life of the <strong>rainscreen</strong> <strong>cladding</strong>.<br />
- Keep dry during installation.<br />
776<br />
Insulation<br />
VAPOUR CONTROL LAYER:<br />
- Material: Rein<strong>for</strong>ced translucent polyethelene sheeting;minimum<br />
nominal thickness 0.37mm<br />
Minimum vapour resistance: 500 MNs/g.<br />
- Lay as work proceeds ensuring continuity and with the minimum of<br />
joints.<br />
- Lap edges of sheets not less than 150 mm and seal with tape. Seal<br />
with tape to pipes, ducts, structural members, etc. which abut or pass<br />
through. Prime substrates as necessary to ensure a full bond over the<br />
width of the tape.<br />
- Tape: Double sided sealant with vapour resistivity not less than the<br />
vapour control sheet.<br />
Size: Mimimum 15mm wide.<br />
- Be<strong>for</strong>e covering check <strong>for</strong> tears and punctures. Carefully repair,<br />
sealing with a lapped patch of vapour control sheet and a continuous<br />
band of sealant tape along all edges.<br />
780<br />
Vapour Control<br />
Layer<br />
July 2001 Page 27 of 27