CIMclad: <strong>Formalised</strong> <strong>per<strong>for</strong>mance</strong> <strong>specifications</strong> <strong>for</strong> <strong>rainscreen</strong> <strong>cladding</strong><br />

______ TEST: Carry out in accordance with ______<br />

(Use this section <strong>for</strong> any specialist test required)<br />

NBS Section H92 660<br />

14 Testing (Contd) -<br />

Additional Tests<br />

IMPACT TEST:<br />

- To CWCT ‘Standard <strong>for</strong> testing of ventilated <strong>rainscreen</strong>s’, clause<br />

3.12.1 and BS 8200.<br />

- Wall category: ______<br />

- Test impact <strong>for</strong> retention of <strong>per<strong>for</strong>mance</strong>: ______<br />

Acceptable damage without impairment of <strong>per<strong>for</strong>mance</strong>:<br />

______<br />

- Test impact to ensure safety to persons: ______<br />

(This test regarded as compulsory by CWCT <strong>for</strong> ground floor<br />

treatments)<br />

661<br />

Impact Resistance<br />

DESTRUCTIVE TESTING OF FIXINGS TO DETERMINE THE<br />

ULTIMATE LOAD:<br />

- Number and location of test fixings: ______<br />

- Test method: To BS 5080-1 and Construction Fixings Association<br />

guidance note ‘Procedure <strong>for</strong> site testing construction fixings’.<br />

670<br />

Strength<br />

SITE FIXINGS TEST:<br />

- Number and location of test fixings: ______<br />

- Test method: To BS 5080-1 and Construction Fixings Association<br />

guidance note Procedure <strong>for</strong> ‘Site testing construction fixings’.<br />

672<br />

SITE SPARGE BAR TEST: To CWCT ‘Standard <strong>for</strong> testing of<br />

ventilated <strong>rainscreen</strong>s’, clause 3.10.3.<br />

(Use to confirm laboratory test results)<br />

680<br />

Water Permeability<br />

July 2001 Page 21 of 21